Section 2 | Important Safety Information - The Outdoor Plus OPT-BP24SQDSSE12 Installation & Operation Manual

Low voltage pans & burners
Table of Contents

Advertisement

SECTION 2
IMPORTANT SAFETY INFORMATION
TECHNICAL SUPPORT, SYMBOL LEGEND, SAFETY INFORMATION FOR INSTALLERS & END-USERS.
Instructions are also available at theoutdoorplus.com, Please carefully follow the instructions in
this manual to prevent personal injury or property loss. Instructions are updated as needed. It is the
installer's responsibility to periodically review instruction for applicable updates.
The steps listed as:
WARNINGS:
Contains information critical to the safe installation and operation of the fire pit.
WARRANTY REQUIREMENT: Must be strictly followed to qualify for product warranty. Warranty will
be void if not followed.
IMPORTANT: Are notes and insights to help ensure product satisfaction and serviceability.
WARNINGS:
It is the installer's responsibility to ensure a safe installation and to educate the end user as to
proper operation. Leave this manual with the end user.
Never alter product or configuration in any way.
We suggest that our products be installed by professionals that are locally licensed by the
authority having jurisdiction in gas piping. We suggest that our products be serviced annually by a
professional certified in the US by the National Fireplace Institute (NFI) as NFI Gas Specialists or in
Canada by WETT (Wood Energy Technical Training). Installer must follow all instructions carefully
to ensure proper performance and safety.
The Outdoor Plus Company, Inc. is not responsible for your actions.
Product is not intended to be a starter for wood or any other combustibles.
Only use gas/fuel type specified for this fire pit see label on the fire pit control Box.
Verify correct gas/fuel type and pressure. Never use an alternative fuel to include bio-fuel, ethanol,
lighter fluid or any other fuel.
Gas pressure and type should be checked prior to use and installation.
DO NOT USE this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas
control which has been under water.
IT IS THE RESPONSIBILITY OF THE INSTALLER TO FOLLOW:
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 or International Fuel Gas Code.
The National Electrical Code, ANSI/NFPA 70.
Local Codes
SUPPLY PRESSURE MIN/MAX:
Natural Gas:
Supply Pressure:
Minimum: 3.5" W.C. .87 kPa
Nominal: 7" W.C. 1.74 kPa
Maximum: 14" W.C. 3.48 kPa
4
THEOUTDOORPLUS.COM | +1 (909) 460-5579 | SUPPORT@THEOUTDOORPLUS.COM
Liquid Propane Gas:
Supply Pressure:
Minimum: 8" W.C. 1.99 kPa
Nominal: 11" W.C. 2.73 kPa
Maximum: 14" W.C. 3.48 kPa