ENCLOSURE CONSTRUCTION
THIS SECTION OUTLINES THE CONSTRUCTION OF THE FIRE FEATURE ENCLOSURE REQUIREMENTS & WARNINGS
WARNINGS:
All fire pits must have a gas shutoff on the outside of the exterior of the fire pit to allow for
emergency shut off and maintenance.
Always use proper materials and construction for gas supply, power and enclosure.
The interior void space of the enclosure surrounding the valve box cannot be filled with any
material (gravel, crushed rock, concrete, etc.)- It is a requirement to have a minimum of 2" under
the valve box for proper ventilation and drainage.
Select materials that are non-combustible in both initial installations as well as over time.
The fire pit assembly should be recessed a minimum of 2.25" from the top of the enclosure to
protect flame from being blown out. Some areas may require more- 4 to 6" is not uncommon.
WARRANTY REQUIREMENT:
The enclosure must be constructed on a stable surface. The weight of the fire pit must be
supported by the pan and not by any control/valve box. For Electronic Ignition Components the
control/valve box must be above grade with adequate drainage to prevent water damage to the
controls inside the box.
IMPORTANT:
Make sure that the structure is level. We recommend the use of the installation collar (optional)
that may be mortared into the surround.
The Outdoor Plus recommends that the pan lip is recessed on trough (linear). The Outdoor Plus
cannot guarantee the lip on all of our products will be perfectly flat and will not warp due to heat.
Product must be accessible for service.
PROPER VENTING
Certain fire pit enclosures may require extra ventilation depending on size, material or extended
use.
1 Square Inch of ventilation is REQUIRED for every 25,000 BTUs.
This is especially important for propane units, as propane gas is heavier than air and can pool in
the bottom of an enclosure.
Venting is required to dissipate heat and any residual fuel. Failure to
WARNING:
provide proper ventilation could result in overheating and or explosion.
10