A foundation of insufficient strength may result in the unit
falling and causing damage and injuries.
• Reinforcement may be necessary for installation by taking
into consideration strong winds, typhoons and earthquakes.
Improper installation may result in the unit falling and
causing accidents.
• Make sure that a separate power supply circuit is provided
for the unit and that all electrical work is carried out by
qualified electricians in accordance with your local laws
and regulations as well as this manual.
An insufficient power supply capacity or improper electrical
operation may lead to electric shocks or fire hazards.
2
indoor unit as far away from fluorescent lamps as possible.
• Install the drain pipe according to the manual to ensure
proper drainage, and insulate the pipe to prevent
condensation.
Improper drain pipe installation may result in water
leakage and household items being wetted.
• Install the indoor unit, outdoor unit, power wiring and
connecting wire at least 1 m away from televisions or
radios to prevent electromagnetic Interference and noise.
(A distance of 1 m or more may not be sufficient to
eliminate the noise for certain waveband of the radios.)