Download Print this page

Techno THB.385.A1A Assembly Instructions

Advertisement

Quick Links

Technical data
Products are a Type 6/6P enclosure ONLY when assembled with a Combined TC and Outdoor are rated cable type (such as
Listed TC/STOOW)
Assembly steps
1a
(a)
(b)
(c)
 Set-up of the male connector
THB.385.xxx: (a) Lock nuts, (b) gasket,
(c) connector housing, (d) connector
insert (male or female)
ASSEMBLY INSTRUCTIONS
Assembly instructions for connector series TH385
Safety Note
 Disconnect power supply before commencing.
 If the preparation and assembly instructions described here are disregarded
then neither safety nor compliance with the technical data can be guaranteed.
 Unconnected connectors must always be protected from pollution (e.g. dust,
humidity, foreign particles, etc.) prior to installation. Do not leave unconnected
(unprotected) connectors exposed to the environment. The usage of Techno
connector sealing caps is strongly recommended.
Part Numbers
Number of poles
Type of connection
Rated Voltage
Rated current
Cable type
Cable size
Cord diameter min – max
Conductor cross section
min - max
Dismantling length
Insulation strip length
Housing color
Insert color
1b
(d)
 Set-up of the plug THB.385.A3F:
(a) Lock nuts, (b) gasket, (c) connector
housing 90°, (d) connector insert (male
or female)
THB.385.A1A
THB.384.B1A
THB.385.A3F
3 poles
Screw connection
20 A
400 V
UL Listed Type TC or TC-ER
12 AWG
Stranded and solid
8.5 mm – 10.2 mm
1.5 sqmm – 4 sqmm
20 mm
8 mm
Black
Natural (THB.385.A1A)
Natural (THB.384.B1A)
Natural (THB.385.A3F)
(d)
(c)
(b)
(a)
 Pass the cable through the lock nut and
2
the gasket and insert it inside the
housing connector. Do not insert the
gasket and the lock nut in the connector
housing

Advertisement

loading

Summary of Contents for Techno THB.385.A1A

  • Page 1  Unconnected connectors must always be protected from pollution (e.g. dust, humidity, foreign particles, etc.) prior to installation. Do not leave unconnected (unprotected) connectors exposed to the environment. The usage of Techno connector sealing caps is strongly recommended. Technical data THB.385.A1A...
  • Page 2 Fig. 3.1 Fig. 3.2  Connect the wires to the male connector  Strip the cable a length of 0.788 inches  Insert the male connector insert in the (20 mm) (Fig. 2.1) insert (or female connector insert) with a housing until it stop.
  • Page 3   Connect the wires to the female The female connector insert and the  Insert the female connector insert in the male connector insert can be inserted in connector insert (or male connector housing until it stop. Make sure the both connector housings (male or insert) with a screw driver.

This manual is also suitable for:

Thb.384.b1aThb.385.a3fThb.384.a1a