Operating Modes; Adjustment; Operation; Maintenance, Repair And Disposal - IFM Electronic efector150 KF Operating Instructions Manual

Capacitive sensors
Hide thumbs Also See for efector150 KF:
Table of Contents

Advertisement

6 Operating modes

6.1 Adjustment

NO
place the target material in the safe
sensing range
>
LED is lit
decrease the sensing range
>
LED goes out
increase the sensing range
>
LED is lit
Do not increase the sensing range beyond Sn.

7 Operation

Check whether the unit operates correctly. Bring about a sensor response by
taking suitable measures.
Display by LEDs:
LED yellow OFF: switching output disabled
LED yellow ON: switching output enabled
Do not operate units with high field intensity (e.g. walkie-talkies) at close range to
the sensor.

8 Maintenance, repair and disposal

The operation of the unit is maintenance-free. To ensure a correct function:
Keep the sensing face and a clear space, if any, free from deposits and foreign
bodies.
When removing the unit or changing the medium, a new adjustment might be
necessary.
It is not possible to repair the unit.
After use dispose of the unit in an environmentally friendly way in accordance with
the applicable national regulations.
6
NC
place the target material in the safe
sensing range
>
LED goes out
decrease the sensing range
>
LED is lit
increase the sensing range
>
LED goes out