Table I. Remote Command Summary - Racal Instruments 1258 Manual

100 mhz switching matrix
Table of Contents

Advertisement

Command
OPEN(@channel_list)
1, 2,3
OPEN:ALL
CLOSe(@channel_list)
CLOSe:STATe?
CLOSe?(@out)
2
UPDAte
LOCK
UNLOck
CONFigure:DIAGnostic
CONFigure:DIAGnostic?
CONFigure:MULTiconnect
CONFigure:MULTiconnect?
CONFigure:AUTOupdate
CONFigure:AUTOupdate?
CONFigure:POWErup
CONFigure:POWErup?
*IDN?
*RST
*TST?
*ESR?
*ESR:DESC?
*CLS
Notes:
1. The <channel_list> parameter can be a single input/output route connection or a list of
input/output routes separated by commas. Each input/output route is specified by using
the syntax: <input_channel>!<output_channel). (i.e., OPEN(@27!45) or
OPEN(@27!45,36!21)
2. If AUTOupdate is not enabled (default), then connections and disconnections are not
performed until the UPDATe command is received.
3. The OPEN and CLOSE commands may optionally be proceeded by ROUTe:.
4. Lowercase letters in the command are optional.
5. On queries returning a binary status, the following applies: 1 = Enabled, On, Pass, 0 =
Disabled, Off, Fail (*ESR? returns 0 for no error, and other than zero for errors)
Operating Instructions 4-10

Table I. Remote Command Summary

Function
1, 2,3
disconnect channel(s)
disconnect all
1, 2,3
connect channel(s)
1, 2,3
return a list of current connections
return input connected to specified output channel
perform all pending connection and disconnection
operations
lock keypad
unlocks keypad
set diagnostic mode
return current diagnostic mode
sets multi-connect mode
return current multi-connect mode
2
sets auto-update mode
return current auto-update mode
2
sets power-up mode
return current power-up mode
returns manufacture, model, version, and matrix size
information
reset the system and run self-test
return results of self-test
return error code of last error that occurred
return character description of last error that occurred
clear the system status
1258 User Manual