TURNING THE SYSTEM ON

1) Connect the emergency stop lanyard to the key switch and your personal flotation
device.
Emergency stop lanyard MUST be securely attached to the operator, and clip MUST
be installed to its switch. DO NOT operate outboard with clip removed from switch,
except in an emergency.
Avoid knocking or pulling clip off the stop switch during normal boating. Avoid
bumping the key if operating without the clip on the switch. The resulting unexpected
loss of FORWARD motion can throw occupants FORWARD causing injury. Keep the
lanyard free from obstructions and entanglements.
At each outing, test the system's operation. With the outboard running, remove clip
from the switch by pulling the lanyard. If the outboard does not stop running, see
your dealer.
2) Move the control lever to the NEUTRAL detent.
3) Turn the main station key switch to ON.
4) The NEUTRAL LED will illuminate.
Troubleshooting Tip: If the system does not turn ON:
• be sure the safety lanyard is connected to the key switch
• check the 3A fuse on the public network power supply cable
• check the 10A fuse on the private network power supply cable
If the NEUTRAL LED is flashing five times per second, a critical fault is present and must be
cleared.
WARNING
N
5