FAULT DETECTION

Type
Condition Code or
Warning
Controllable
Critical
A critical fault will prevent normal operation and result in the system entering a failed state.
The control will:
• send "not available" data in the throttle and gear messages
• deactivate NEUTRAL Throttle Warm-Up mode
• send the fault message and/or alarm
• store the fault in memory
• flash the appropriate control head LED(s) five times per second
• When the control detects that the outboard is in NEUTRAL idle and the working lever is in
NEUTRAL, the system returns to normal operation.
16
Description
A conditional fault
requiring remedial
action to correct
that does not affect
normal operation.
Example: Attempt
to start outboard(s)
with control lever(s)
not in NEUTRAL.
Faults that allows
for a fully controlla-
ble remedial action.
Example: Low bat-
tery voltage.
Faults that result in
the inability to accu-
rately determine
critical outboard
commands.
Example: Commu-
nication between
the control and out-
board(s) EMM(s) is
lost.
Response
Response based on
condition - upon
resolution the sys-
tem will resume full
performance.
Informational only.
Commanded lever
and gear positions
become unavail-
able. Outboards set
to SAFE mode.
Indication
Condition specific
warning message
shows on gauge or
display.
NEUTRAL LED
flashes five times
per second.
Warning message
shows on gauge or
display.