Chapter Vi Code System; All Code System; Codabar - Waveshare Barcode Scanner Module B Setup Manual

Table of Contents

Advertisement

CHAPTER VI CODE SYSTEM

ALL CODE SYSTEM

If the barcode scanning device needs to solve all code systems, please scan the "All code systems
on" barcode. For specific code system only, scan the "All code system off" barcode and then scan
All Code Systems On
the "All code systems on" barcode for that specific code system.
NOTE: The 2D ZIP Code is not turned on by default when the "All code systems on" barcode is
scanned. The 2D ZIP Code must be turned on separately.
Code Reading Length Description
If the scanned barcode data length does not match the valid reading length, the device will sound
an error tone. Setting the same value for the minimum and maximum length will force the device
to read a fixed length barcode. This helps to reduce misreading.
For example, only barcodes with a barcode length of 6-10 characters can be solved. The minimum
length =06, and the maximum length =10.
1.
Select the code system to set the maximum and minimum reading length, scan the "Minimum
Barcode Length" barcode under its directory, and scan the number "6" barcode and "Save"
barcode from the appendix chart.
2.
Scan the "Maximum Barcode Length" barcode, and scan the numbers "1", "0" and "Save"
barcodes from the appendix chart.
The above steps will set the maximum reading length of the selected code system to be 10 and the
minimum reading length to be 6.

CODABAR

All Default Codabar Settings