Disassembly advice
LIGHT STRIP CAP ASSY 1
INLAY AND LIGHT STRIP ASSY 2
REFLECTOR MOLDED 3
LED MICROSWITCH HOLDER ASSY 4
TRIGGER SPRING 5
TRIGGER MOLDED 6
MICA PLATE 7
PLASTIC WASHER (1x) 8 (FRONT)
DECORATION CAP PRINTED 9
Remove
Screw A
Disassemble
LIGHT STRIP 1
Fig 1. Using "-" screw driver to lift up the Inlay and
release the catch at the end of the handle.
Fig . Position of the catch to be applied forces
at the end of the handle.
Iron
Apply forces
GC1615
Remove
Screw B
Disassemble
INLAY AND LIGHT STRIP ASSY 2
Disassemble
REFLECTOR MOLDED 3
Remove
Screw C
Disassemble
LED MICROSWITCH HOLDER ASSY 4
Disassemble
TRIGGER SPRING 5
Disassemble
TRIGGER MOLDED 6
Remove
Screw D
Disassemble
MICA PLATE 7
Disassemble
PLASTIC WASHER (1x) 1
Remove
Screw E1, E2
Remove
Screw F
Disassemble
DECORATION CAP PRINTED 8
RYTON RING 10
DEVIATOR HOUSING MOLDED 11
IRON THERMISTOR ASSY 12
PLSTIC WASHER (2x) 8 (REAR)
HOSE CORD MOUNTED ASSY 13
HOUSING PRINTED 14
SOLEPLATE MOUNTED ASSY 15
Remove
Screw A
Disassemble
LIGHT STRIP 1
Remove
Screw B
Disassemble
INLAY AND LIGHT STRIP ASSY 2
Disassemble
REFLECTOR MOLDED 3
Remove
Screw C
Remove
Screw E1, E2
Remove
Screw D
Disassemble
MICA PLATE 7
Disassemble
PLASTIC WASHER (1x) 1
Disassemble
RYTON RING 10
Remove
Screw G1
Disassemble
DEVIATOR HOUSING MOLDED 11
Remove
Screw H
Disassemble
IRON THERMISTOR ASSY 12
Remove
Screw I1, I2
Disassemble
PLASTIC WASHER (2x) 1
Disconnect
Wires
Release
Hose clip (2x)
Remove
Screw J
Disconnect
Wires
Disassemble
HOSE CORD MOUNTED ASSY 13
Disassemble
HOUSING PRINTED 14
Disassemble
SOLEPLATE MOUNTED ASSY 15
RI1645