Repair Instruction
5.3. Enter Self Check mode Process Flow Chart
Start
Press and hold Power
& ECO buttons
Turn on mains power /
Plug in mains cord without
releasing buttons
Rinse LED
turns on?
YES
Release buttons,
Rinse LED will
remain on for 3 sec
Wait for at
least 5 sec
NO
Turn off mains power /
Unplug in mains cord
Press steam trigger twice
within 1 sec before
Rinse LED turns off
GC1615
If fail to enter Self-Check mode,
could be due to:
1.
No power to PCBA
2.
Button(s) malfunction
3.
Steam trigger malfunction
4. Timing incorrect
*
Refer to Trouble shooting tip #5
- trigger press is not detected
Enter
Self-Check mode
successfully?
Entered
Self-Check mode
RI1645
*
NO
YES
30-33