MODEL HP 01-C
THERMOSTAT
24 VAC HOT
R
24 VAC COMM
C
HEAT STAGE 1
W/W1
COOL STAGE 1
Y/Y2
FAN
G
HEAT STAGE 2
O/W2/B
N/A
Y1
N/A
B
OUTDOOR
S1
SENSOR
S2
CONNECTION
Fig. 6—Single-Speed Air Conditioner
with Typical Fan Coil
MODEL 2S 01-C
SINGLE-STAGE
THERMOSTAT
24 VAC HOT
R
24 VAC COMM
C
HEAT STAGE 1
W/W1
COOL STAGE 2
Y/Y2
FAN
G
N/A
O/W2/B
COOL STAGE 1
Y1
N/A
B
S1
OUTDOOR
SENSOR
S2
CONNECTION
Fig. 8—Two-Speed Air Conditioner
with Single-Stage Furnace
TYPICAL
SINGLE-SPEED
FAN COIL
AIR CONDITIONER
R
C
C
W2
*
Y
Y
G
W3
E
See notes 2, 4, 6, 10 and 11
A98455
TWO-SPEED
FURNACE
AIR CONDITIONER
R
R
C
C
W
Y
Y2
G
HUM
Y1
See notes 2, 5, 8 and 11
MODEL HP 01-C
THERMOSTAT
24 VAC HOT
24 VAC COMM
FAN
COOL/ HEAT
STAGE 1
HEAT STAGE 2
RVS COOLING
N/A
N/A
OUTDOOR
SENSOR
CONNECTION
Fig. 7—Single-Speed Heat Pump
MODEL 2S 01-B
THERMOSTAT
24 VAC HOT
24 VAC COMM
HEAT STAGE 1
COOL STAGE 2
FAN
HEAT STAGE 2
O/W2/B
COOL STAGE 1
N/A
OUTDOOR
SENSOR
CONNECTION
A04009
Fig. 9—Two-Speed Air Conditioner
with 2-Stage or Variable-Speed Furnace
8
TYPICAL
FAN COIL
R
R
C
C
G
G
*
Y
Y/Y2
W/W1
W2
W3
E
O/W2/B
Y1
B
S1
See notes 6, 7, 10 and 11
S2
with Typical Fan Coil
TWO-STAGE OR
VARIABLE-SPEED
FURNACE
R
R
C
C
W/W1
W/W1
Y/Y2
Y/Y2
G
G
ACRDJ
W2
Y1
Y1
HUM
B
S1
See notes 2, 3, 4, 8, 9 and 11
S2
SINGLE-SPEED
HEAT PUMP
R
C
Y
W2
O
A98456
TWO-SPEED
AIR CONDITIONER
R
C
Y2
Y1
A04010
Need help?