TROUBLE SHOOTING GUIDE
Before requesting any service on your unit, please check the following points. Please
note that this guide serves only as a reference for solutions to common problems.
SYMPTOM
Compressor
not Fuse blown or circuit breaker
running.
Condensing
unit Excessive amount of warn
runs
for
long product placed in cabinet.
periods of time.
Cabinet
temperature is
too
warm.
POSSIBLE CAUSE
tripped.
Power cord unplugged.
Thermostat set too high.
Cabinet in defrost cycle.
Prolonged door opening or
door ajar.
Door gasket(s) not sealing
properly.
Dirty condenser coil.
Evaporator coil iced over.
Thermostat set too warm.
Blocking air flow.
Excessive amount of warm
product placed in cabinet.
Fuse blown or circuit breaker
tripped.
Dirty condenser coil.
Prolonged door opening or door
CORRECTIVE ACTION
Replace fuse or reset circuit
breaker.
Plug in power cord.
Set thermostat to lower
temperature.
Wait
for
defrost cycle to
finish.
Allow adequate time for
product to cool down.
Ensure doors are closed
when not in use. Avoid
opening doors for long
periods of time.
Ensure gaskets are
snapped in completely.
Remove gasket and wash
with soap and water. Check
condition of gasket and
replace if necessary.
Clean the condenser coil.
Unplug unit and allow coil to
defrost. Make sure
thermostat is not set too
cold. Ensure that door
gasket(s) are sealing
properly.
Set thermostat to lower
temperature.
Re-arrange product to allow
for proper air flow. Make
sure there is at least four
inches of clearance from
evaporator.
Allow adequate time for
product to cool down.
Replace fuse or reset circuit
breaker.
Clean the condenser coil.
Ensure doors are closed