Check item
The contact lenses may have
not been on the appropriate
position.
You may have been wearing
color contact lenses.
G Cases of Enrollment/Recognition Failure
• You have closed your eyes or not opened your eyes widely during capturing.
• You were wearing sunglasses whose lens color is too deep to be captured
• Smudges were sticking on the glasses.
• You were not looking at the mirror during capturing.
• Your position is too near or too far from the iris reader to be captured.
When you come within approx. 50 cm {1.64 ft.} of the iris reader, the guidance will start. The recognition range between the
eyes and mirror is approx. 30 cm to 40 cm {0.98 ft. to 1.32 ft.}.

I Before Requesting for Repair

Check to see the following before requesting for repair.
Do not attempt anything other than the described actions herein.
If the trouble cannot be corrected even after checking and trying remedy, contact your dealer.
Problem
The live indicator does not
light up.
Enrollment/Recognition is
invalid.
If a lens has slipped off the eye's corneal surface, the contact edge may hide the
iris images. That may cause invalid recognition. In this case, move the contact
lens back to the corneal surface by blinking.
Depending on the lens type, recognition may be invalid.
Check item
• Power may not be supplied to the iris
reader.
• The indicator is set not to light up by the
administration software.
• Your iris data may not be enrolled in the
iris reader.
• You may not have passed your card cor-
rectly through the card reader (if a card
reader is used).
• A smudge may be on the front panel or
the panel may be damaged.
Remedy
Remedy
Refer to system administrators.
Refer to system administrators.
Refer to p. 11.
(If the front panel needs
replacement, refer to service
personnel.)