Sl 80-399 propane conversion

Advertisement

Quick Links

DANGER
Check the rating plate of the
boiler to ensure it is configured
for the fuel you are using.
Failure to perform the proper fuel
conversion when required can
result in an immediate hazard.
Operating any IBC boiler using
a fuel other than the fuel listed
on its rating plate is prohibited.
If these instructions are not
followed exactly, a dangerous
situation can result, leading to
fire, explosion or production of
carbon monoxide, which may
cause property damage, personal
injury, or loss of life.
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, an explosion or production of carbon monoxide may
result causing property damage, personal injury or loss of life. The qualified service agency is responsible
for the proper installation of this kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer's instructions supplied with the kit.
120-191 R1
SL 80-399
ProPAne conversion PArts Kit# P-175
NOTE
These instructions are to be closely followed, and referenced to the
details in the boiler's current certified Installation and Operating
Instruction Manual.
The above listed modulating boilers are factory fire-tested to operate with
natural gas, or propane as ordered. The rating plate will be marked to indicate
which fuel the particular boiler has been set up with. Firing a boiler with a fuel
other than what is listed on the rating plate is prohibited unless the following
conversion procedure is completed by a qualified technician.
The boiler will automatically de-rate the maximum input at a rate of
approximately 2% per 1,000' above 4,500'. The gas valves zero governor will
ensure that the gas:air mixture is not affected at altitude.
Important Note: If converting from Propane to Natural Gas - Order
Propane to Natural Gas Conversion Kit, IBC Part# P-177 from your
authorized IBC Distributor.
MODEl NuMbER
SL 80-399
Table 1: Fuel Conversion Kits
WARNING
Included wIth conversIon KIt
(IBC ParT# P-175)
1 x rating Plate Fuel Overlay - IBC Part# 080-115
1 x Gas Valve Conversion Label - IBC Part# 080-107B
1 x Installer Identifier Label - IBC Part# 080-171a
1 x Instruction Sheet - IBC Part# 120-191
NATuRAl GAs
TO PROPANE
P-175
PROPANE TO
NATuRAl GAs
P-177
1

Advertisement

loading

Summary of Contents for IBC P-175

  • Page 1 Important Note: If converting from Propane to Natural Gas - Order fire, explosion or production of Propane to Natural Gas Conversion Kit, IBC Part# P-177 from your carbon monoxide, which may authorized IBC Distributor. cause property damage, personal injury, or loss of life.
  • Page 2 SL 80-399 ProPAne conversion PArts Kit# P-175 Refer to the details in the boiler’s current Installation and Operation cAuTiON Manual, section 3.3 - “COMMISSIONING”, 3.4 “FUEL CONVERSION” The gas supply shall be shut The Low Fire (Zero-offset) valve adjustment cap on the gas valve has been off prior to disconnecting factory set.
  • Page 3 SL 80-399 ProPAne conversion PArts Kit# P-175 Turn off the boiler’s gas shut off valve. With a small (1/8” or 3 mm) flat MODEl HiGH fiRE screwdriver, open the inlet gas supply pressure test port by turning its NuMbER iNPuT center-screw 1 full turn counterclockwise.
  • Page 4 SL 80-399 ProPAne conversion PArts Kit# P-175 NOTE The Installer must fill in the information and affix the included fuel conversion labels to the boiler in the positions indicated after the conversion is completed 120-191 R1...