5. DIP Switch
6. RFU-433 Utility
Users can select "Hardware Setting" or "Software Setting" through the utility. If
use "Hardware Setting", the "Channel" parameter will be fixed at 433.5 MHz, the
"Output Power" parameter will be fixed at 10 dBm, and the "Message Duty"
parameter will be fixed at enable 10% message duty. If use "Software Setting", the
"Channel", "Output Power" and "Message Duty" parameters can be set by users.
RFU-433 Quick Start v1.00, January 11, 2019
No
Switch Name
1 ~ 3
Group ID
4 ~ 6
reserved
COM
7 ~ 8
data type
Set mode/Run mode
Description
RFU-433
with
group ID can communicate
with each other
reserved
Data Type
N, 8, 1
OFF
O, 8, 1
ON
E, 8, 1
OFF
Repeater
ON
Set
Utility setting mode
Run Normal firmware work
-------------------------------------
the
same
7
8
OFF
OFF
ON
ON