Mounting the prepared cables in the connection cover

How are the
The following sequence should be maintained when installing the pre-
prepared cables
pared cables into the connection cover (refer to Fig. 2-24):
installed?
1. Release the nut, dummy plugs and terminal insert/seal from the
2. Locate the nut and clamping insert/seal onto the cable.
3. Open–up the shield braiding (remove the insulating foil below).
4. Assemble the nut with clamping insert/seal.
5. Insert these into the PG gland and tighten the nut.
6. Connect the ends of the cables to the lower side of the connection
Fig. 2-24 How are the prepared cables installed?
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
PG gland.
The shield must cover the O ring by approx. 2 mm.
Cleanly cut–off excessive shield!
cover.
Ó
Point 1
Ó
Nut
Cap
Clamping insert/seal
Point 2
Ó
Point 3
Ó
Point 3
Ó
Ó
Connection to the PROFIBUS unit
Point 4
Ó Ó
Point 5
Ó Ó Ó Ó
Ó Ó
2 Installing and Connecting–Up
2.4 Mounting SIMODRIVE POSMO A
M20 gland
O ring
M20 gland
Wiring at
X20
2
Shield
Point 6
2-55