The Globe Quick Response GL5614 Extended Coverage Pen-
dent Sprinkler for Light Hazard occupancies is a low profi le yet
durable design which utilizes a 3mm frangible glass ampule as
the thermosensitive element. This provides sprinkler operation
approximately six times faster than ordinary sprinklers. While this
Quick Response Sprinkler provides an aesthetically pleasing ap-
pearance, it can be installed wherever standard light hazard ex-
tended coverage pendent sprinklers are specifi ed; but offers the
additional feature of greatly increased safety to life. Quick Re-
sponse Sprinklers should be used advisedly and under the direc-
tion of approving authorities having jurisdiction, in accordance with
their listings and in accordance with NFPA 13.
The heart of Globe's Series GL-QR sprinkler proven actu-
ating assembly is a hermetically sealed frangible glass ampule
that contains a precisely measured amount of fl uid. When heat is
absorbed, the liquid within the bulb expands increasing the inter-
nal pressure. At the prescribed temperature the internal pressure
within the ampule exceeds the strength of the glass causing the
glass to shatter. This results in water discharge which is distrib-
uted in an approved pattern.
T
ECHNICAL
See reverse side for Approvals and Specifi cations.
Temperature Ratings -
135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C)
Water Working Pressure Rating - 175 psi (12 Bars)
Factory tested hydrostatically to 500 psi (34 Bars)
Maximum low temperature glass bulb rating is -67°F (-55°C)
Frame - bronze
Bulb seat - copper
Bulb - glass with alcohol based solution, 3mm size
Escutcheon Assembly - steel
SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
CLASSIFICATION
ORDINARY
INTERMEDIATE
DEC 2017
O
PERATION
D
ATA
Defl ector - brass
Screw - brass
Spring - nickel alloy
AVAILABLE SPRINKLER
TEMPERATURES
135°F/155°F
175°F/200°F
Q
UICK
E
XTENDED
L
A
UTOMATIC
P
ENDENT
Seal - tefl on
BULB COLOR
57°C/68°C
ORANGE/RED
79°C/93°C
YELLOW/GREEN
R
ESPONSE
C
OVERAGE
H
IGHT
AZARD
S
PRINKLERS
GL5614
R
ECESSED
SERIES GL-QR/ECLH
EXTENDED COVERAGE
PENDENT
SERIES GL-QR/ECLH
EXTENDED COVERAGE
RECESSED PENDENT
N.F.P.A. MAXIMUM CEILING
TEMPERATURE
100°F
150°F
P
ENDENT
38°C
66°C
GFS-200 (Formerly A-42)

Advertisement

loading

Summary of Contents for Globe GL-QR/ECLH Series

  • Page 1 Sprinklers should be used advisedly and under the direc- tion of approving authorities having jurisdiction, in accordance with their listings and in accordance with NFPA 13. The heart of Globe's Series GL-QR sprinkler proven actu- SERIES GL-QR/ECLH ating assembly is a hermetically sealed frangible glass ampule EXTENDED COVERAGE that contains a precisely measured amount of fl...
  • Page 2 1" MIN. 1 3/4" MAX. ® LOBE RODUCT ARRANTY RDERING NFORMATION Globe agrees to repair or replace any of its own manufactured SPECIFY products found to be defective in material or workmanship for a • • • • Quantity Style Orifi...
  • Page 3: Description And Operation

    NFPA 13. SERIES GL-QR/ECLH The heart of Globe's Series GL-QR sprinkler proven actuating as- EXTENDED COVERAGE sembly is a hermetically sealed frangible glass ampule that contains PENDENT a precisely measured amount of fl...
  • Page 4 3/4” ADJUSTMENT RECESSED PENDENT ® RDERING NFORMATION LOBE RODUCT ARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured • • • products found to be defective in material or workmanship for a • Quantity Style Orifi ce period of one year from date of shipment.
  • Page 5 EXTENDED COVERAGE jurisdiction and in accordance with their listings. LIGHT HAZARD The heart of Globe's GL1112 sprinkler proven actuating PENDENT assembly is a hermetically sealed frangible glass ampule that GL1112 contains a precisely measured amount of fl uid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure.
  • Page 6: Warranty

    RODUCT ARRANTY RETAINER 1 1/2" MAX. Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a RECESSED PENDENT period of one year from date of shipment. For specifi c details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List).
  • Page 7 The Globe Series GL-ECOH Ex- tended Coverage Ordinary Hazard Extra Large Orifi ce Sprin- kler is to be installed per NFPA 13 guidelines. The heart of Globe's Series GL sprinkler proven actuat- SERIES GL-ECOH ing assembly is a hermetically sealed frangible glass ampule EXTENDED COVERAGE that contains a precisely measured amount of fl...
  • Page 8 7/8" MAX. ® LOBE RODUCT ARRANTY CEILING Globe agrees to repair or replace any of its own manufactured 1/8" RETAINER 1" MIN. products found to be defective in material or workmanship for a 1 3/4" MAX. period of one year from date of shipment.
  • Page 9 HORIZONTAL SIDEWALL their listings and in accordance with NFPA 13. The heart of Globe’s Series GL-QR sprinkler proven actuating as- sembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fl uid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure.
  • Page 10 LOBE RODUCT ARRANTY • Quantity - Wrenches - P/N 325390 Globe agrees to repair or replace any of its own manufactured • Quantity - Recessed Escutcheons products found to be defective in material or workmanship for a • Quantity - Recessed Wrenches - P/N 325391 period of one year from date of shipment.
  • Page 11 NFPA 13. This sprinkler series is available in various temperature ratings and several fi nishes to meet many varying design requirements. The heart of Globe's Series GL-ECLH sprinkler proven SERIES GL-ECLH/SW actuating assembly is a hermetically sealed frangi- EXTENDED COVERAGE...
  • Page 12 1 29/32" DIA. ® LOBE RODUCT ARRANTY 1" MIN. Globe agrees to repair or replace any of its own manufactured 1 3/4" MAX. 1" MIN. products found to be defective in material or workmanship for a 1/8" 1 1/2" MAX.
  • Page 13 ESCRIPTION AND PERATION The Globe GL5603 Extended Coverage One Inch Adjustable Concealed Pendent Sprinkler for Light Hazard occupancies has a flat plate profile that utilizes a 3mm frangible glass ampule as the thermo- sensitive element. It features economy, aesthetics and the lowest allowable water flow with a nominal 1"...
  • Page 14: Cross Section

    NOTE: METRIC CONVERSIONS ARE APPROXIMATE. FINISHES AVAILABLE ON SPECIAL ORDER. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. ***FACTORY PAINTED COVER PLATES MUST NOT BE REPAINTED. NON-FACTORY APPLIED PAINT MAY ADVERSELY DELAY OR PREVENT SPRINKLER OPERATION IN THE EVENT OF A FIRE.
  • Page 15 The heart of Globe’s Model Series GL-QR sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. The 3mm frangible glass...
  • Page 16 Other Painted Finishes NOTE: METRIC CONVERSIONS ARE APPROXIMATE. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. FINISHES AVAILABLE ON SPECIAL ORDER. ***FACTORY PAINTED COVER PLATES MUST NOT BE REPAINTED. NON-FACTORY APPLIED PAINT MAY ADVERSELY DELAY OR PREVENT SPRINKLER OPERATION IN THE EVENT OF A FIRE.
  • Page 17 The heart of Globe’s Model Series GL-QR sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. At the rated temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter.
  • Page 18 Other Painted Finishes NOTE: METRIC CONVERSIONS ARE APPROXIMATE. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. FINISHES AVAILABLE ON SPECIAL ORDER. ***FACTORY PAINTED COVER PLATES MUST NOT BE REPAINTED. NON-FACTORY APPLIED PAINT MAY ADVERSELY DELAY OR PREVENT SPRINKLER OPERATION IN THE EVENT OF A FIRE.

This manual is also suitable for:

Gl5614