TROUBLESHOOTING GUIDE
General Problem
ELECTRICAL (Continued)
Improper or No High
Voltage (Cont.)
Isolation System
Grounded Out
www.carlisleft.com
Return To Contents
Possible Cause
Faulty flow switch
Improper or no ground at control unit
Faulty high voltage cable
Faulty control PC board
Faulty high voltage multiplier assembly
Missing conductive sponge in resistor tube
Faulty resistor tube assembly
Failed fluid hose
Insolation stand or charged
equip-ment too close to ground
Replace flow switch.
Trace and correct.
Replace.
Replace.
Check and replace.
Install.
Replace.
Replace fluid hose.
Provide adequate ground distance.
47 / 72
MAINTENANCE
Solution
AH-06-02-R17 (06/2022)