MAINTENANCE
8. Remove the trigger stop by turning the knob of the stop
counter-clockwise until the thread of the stop is completely
disengaged.
1
Figure 26: Trigger Stop Removal
TRIGGER STOP REMOVAL
Item #
1
Trigger Stop Assembly
Reassembly
(Refer to Figures 21, 22, 23, 24, 25, 26, and 27)
1. Screw the trigger stop into the handle in a clockwise
direction.
2. Push the finger shelf up on the dovetail pad on the handle
to the desired height, insert the set screw, and tighten
with a 3/32" Allen wrench.
3. Insert the fluid bracket over the air fitting, then install
the o-ring over the air fitting. Tighten the air fitting in a
clockwise direction.
AH-06-02-R17 (06/2022)
Return To Contents
Description
Figure 27: Hook Insertion Into Handle
4. Push the hook gasket into the groove of the hook. Apply
a light coat of dielectric grease (LSCH0009) to the hook
gasket exterior and slide the hook into position.
5. Reinstall the air valve components in the reverse order
of disassembly.
6. Push the rear cover onto the back of the handle. Secure
the cover by inserting the fan air adjustment valve into
the handle and tighten in the clockwise direction.
7. Insert the barrel gasket back into the handle.