11. Playback Mode

This item lets you select the ID code for playback of
recorded video tape.
1. Move the cursor to the PLAYBACK MODE para-
meter.
2. Select FIELD or FS10 by pressing the LEFT or
RIGHT button.
The initial factory setting is FIELD.
FIELD: Normal position.
FS10: Enables playback of a tape that is
recorded on the WJ-FS10.

12. Data Mode

This item lets you select an external controller from
the data port.
1. Move the cursor to the DATA MODE parameter.
2. Select CU550A or PC by pressing the LEFT or
RIGHT button.
CU550A: Enables control from the WV-CU550A
System Controller.
PC: Enables control from a PC.
The initial factory setting is CU550A.
13. RS-232C Mode
This item lets you select the RS-232C port for con-
trol of the VCR, or for external control of the system
from a PC.
1. Move the cursor to the RS-232C MODE para-
meter.
2. Select VCR or PC by pressing the LEFT or
RIGHT button.
VCR: Enables use as VCR control port.
PC: Enables use as external control port from a
PC.
The initial factory setting is VCR.
Note: Be sure to select PC on this menu if you
plan to use the REMOTE OUT connector for
controlling the VCR.

14. Communication Port Setup

This item lets you set the parameters for communi-
cation between the ports and the connected appli-
ances.
1. Move the cursor to COM PORT SETUP, then
press the SET button. The COM PORT SETUP
table shown below appears on the monitor
screen.
DELAY
BAUD RATE
WAIT TIME
DATA BIT
PARITY
STOP BIT
XON/XOFF
FULL/HALF
2. Move the cursor to the port you want to edit by
pressing the Direction Arrow Buttons.
3. Select the desired Delay Time in the DELAY
area
by
Decrement (–) button.
4. Select the desired Baud Rate in the BAUD
RATE area by pressing the Increment (+) or
Decrement (–) button.
5. Select the desired Wait Time in the WAIT TIME
area
by
Decrement (–) button.
6. Select 7 or 8 in the DATA BIT area by pressing
the Increment (+) or Decrement (–) button.
7. Select the desired Parity Check in the PARITY
area
by
Decrement (–) button.
8. Select 1 or 2 in the STOP BIT area by pressing
the Increment (+) or Decrement (–) button.
9. Select ON or OFF in the XON/XOFF area by
pressing the Increment (+) or Decrement (–)
button. (except RS-232C)
10. Select FULL or HALF Duplex in the FULL/HALF
area
by
Decrement (–) button. (RS-485 only)
11. Repeat the above procedures to edit other
ports.
12. Press the SETUP/ESC button to execute the set-
ting and return to the previous SYSTEM SETUP
menu.
-35-
COM PORT SETUP
RS-232C DATA
RS-485
OFF
OFF
OFF
9600
9600
19200
OFF
100
OFF
7
8
8
ODD
EVEN
NONE
1
1
1
-
OFF
OFF
-
-
FULL
pressing
the
Increment
pressing
the
Increment
pressing
the
Increment
pressing
the
Increment
(+)
or
(+)
or
(+)
or
(+)
or