The unit, in a combination with a welding
helmet or a hard hat, is not recommended for
users with beard or long hair extending to the
respiratory zone.
Beware of a higher CO concentration in the air
supply, which may occur if the compressor
does not work properly, when the lubricating oil
sometimes burns due to high temperatures.
The supply air pressure must be within the
range between 300 and 1000 kPa.
The supply pressure hoses may only be
located in such places of the workplace where
they cannot be damaged.
The maximum working pressure of the hoses
supplied to CA Pressure and CAP Conditioner,
order no. 610030 and 610036, is 1000 kPa.
Pressure hoses for CA Pressure and CAP
Conditioner, order no. 610030 and 610036, are
not antistatic and the maximum temperature to
which they are resistant without damage is
70°C.
The maximum length of the hose from the
compressed air distribution or CA Conditioner
to the unit must not exceed 10 m (not
applicable to CA Pressure for mask for which
the hose length is not limited).
The recommended temperature range of use is
10-40°C; at lower temperatures, the use of the
protective hood with air supply may be
unpleasant. The lowest allowable temperature
for use of CA Pressure and CA Conditioner is
10°C.
Before
connecting
distribution, it is necessary to check what
medium is in the line and what is its quality. For
the CA Pressure units, it is necessary to
provide breathable air according to EN 12 021.
The CA Pressure units can be combined with
the types of head parts shown in the pictorial
annex. It shows also classes for the respective
combinations.
Information on head parts are provided in the
instructions for use of the CA head parts.
If any principles stated in this manual are
breached, the warranty becomes null and void!
3. Unpacking / Assembly / Use and
Functions
3.1. Unpacking CA Pressure
Check that the delivery is complete and no damage
occurred during transport.
Content of the CA Pressure (63 00 00P), CA
Pressure FC (64 00 00P) assembly
CleanAIR Pressure unit
Belt for the unit
Air hose
Air flow indicator
Instructions for Use
__________________________________________________________________________________
the
unit
to
the
air
1 pc
1 pc
1 pc
1 pc
1 pc
CA Pressure for mask (65 00 00P):
CleanAIR Pressure for mask including
hose
Belt for the unit
Air flow indicator
Adaptor for mask connection
Instructions for Use
We recommend using CA Conditioner with CA
Pressure in order to guarantee the supplied air
quality, unless the air in the compressed air
distribution system is treated to the quality
according to EN 12 021.
Content of the CA Pressure Conditioner assembly
CA Pressure Conditioner unit
Unit stand
Screws for connecting the unit to the stand
Washer
Instruction for Use
3.2. Assembly
CA Pressure / CA Pressure FC + CAP
Conditioner
1. Check that all components are in good
condition, i.e. without apparent damage.
2. Connect CAP Conditioner to the compressed
air
distribution
compressor. The air source must be equipped
with a safety valve. (If CAP Conditioner is not
used, the compressed air supply is connected
straight to CA Pressure.). Attach the enclosed
hose connector and screw it in.
3. It is recommended using only original hoses
supplied by the manufacturer and certified
according to the applicable standard.
4. Check that the air pressure in the distribution
system corresponds to the range 300 to 1000
kPa.
5. Attach the unit onto your belt and fit the
connecting hose to it.
6. Using the quick coupling, connect the pressure
hose from the compressed air source to the CA
Pressure unit. The hose from CAP Conditioner
to CA Pressure must not be longer than 10
metres.
7. Check the air flow according to Chapter 4.2.
The lowest allowable flow rate is 170 l/min.
3.3. Assembling CA Pressure for mask
1. Check that all components are in good
condition, i.e. without apparent damage.
2. Connect CAP Conditioner to the compressed air
distribution system or straight to a compressor.
The air source must be equipped with a safety
valve. (If CAP Conditioner is not used, the
compressed air supply is connected straight to
CA Pressure.)
3. It is recommended using only original hoses
supplied by the manufacturer and certified
according to the applicable standard.
3
system
or
straight
1 pc
1 pc
1 pc
1 pc
1 pc
1 pc
1 pc
2 pcs
4 pcs
1 pc
to
a

Advertisement

Table of Contents
loading

Table of Contents