5 Technical data

Case:
Rail according to DIN EN 50022 (35 x 7,5 mm)
W x D x H:
(26 x 75 x 111) mm
Protective class IP 40
Polyamid, light-grey (RAL 7035)
CE marking:
The device is CE proofed.
Environment:
Operating temperature
Storage temperature
Humidity (non condensing)
Specifications for the pulse-generator-impulse contact
Potential
Resistance
Capacity (with cable)
Minimum contact duration
Minimum interval between 2 pulses 40 ms
Maximum pulse frequency
PadPuls contact input
Contact voltage
Contact current
Guaranteed debounce time
Connection cable
S
-Interface
0
Supply voltage
Detecting level
Current limit
Guaranteed debouncing time
14
26.09.01, Version 1.3
GmbH, Stettiner Str. 38, D-33106 Paderborn
0°C .. 60°C
-25°C .. 60°C
10% .. 70%
Floating, insulation to earth > 1MΩ
Open > 10MΩ, closed < 10kΩ
< 2 nF
5 ms
12,5 Hz with pulse length = pause length (1:1)
2.5V to 3.4V
2µA to 4µA
1.2ms
Maximum 2 m twisted pair with shielding
connected only on the PadPuls side
12VDC to 27VDC, minimum 30mA
4mA
20mA
0.25ms
26
75
111
PadPuls M1C User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Im001gc