Linde Warning Projector 85 pro Manual page 9

Table of Contents

Advertisement

Available languages

Available languages

4. Connecting a Potential-free Contact
or a 1-10V Control
4.1 Use of the Connector
1. Choose a suitable cable with at least 2 con-
ductors according to the specifications in
the drawing.
2. Remove the insulation at the end of the
cable according to the specifications in the
drawing.
4.2 Assignment
NOTE: Using the Push-Lock connection
Flexible conductors without ferrules or con-
ductors with large cross-sections can be easily
connected using the levers. The terminal point
is completely opened by the coloured lever and
remains in this open position. The conductor
connection is made by closing the lever. Wire
rigid conductors and conductors with ferrules
easily: through direct insertion. The contact
point does not have to be opened first. To dis-
connect a connected conductor, the lever is
moved to the open position and the terminal
point is opened. The conductors can then be
removed with ease
4.3 Closing the Connector
1. Close the connector according to the spe-
cifications in the drawing.
2. Connect the control cable with the con-
nector to the projector's control port and fix
the connector with the knurled nut.
Supplementary usage information: device control connections
Ø 4 - 8 mm
5
4
3
1
2
15
15
15
1.5 Nm
24
0.14 - 0.75 mm²
AWG 26 - 18
blue
brown
+
0.4 Nm
0.4 Nm
7
9

Advertisement