INSTALLATION AND OPERATION MANUAL, DIRECT STEAM FULL JACKET TILTING KETTLES,
MODELS: DLT-20F, DLT-30F, DLT-40F, DLT-60F
6.0 TROUBLESHOOTING (Continued)
AIR VENTING (Continued)
In the initial stages of the cooking process when the steam comes in contact with the cold kettle
bowl surface, it condenses and forms a large amount of water. The condensate water must be
removed from the kettle jacket in order for the kettle to function adequately. The ball valve
located at the base of the kettle jacket may be opened to remove the water. It may be
necessary to repeat this procedure several times depending on the number of batches being
cooked as each batch will create condensate. If the kettle appears to be slow in heating, this
would indicate that there is water in the jacket. Open ball valve and drain. Close valve and
commence operation of the kettle.