5 Installation
Indoor unit in­
Refrigerant
stallation
charge
height
1.8 m
factory -
maximum
2.2 m
factory -
maximum
5.5.4

Installing the mounting bracket

Fig.115
5.5.5

Refrigerant pipes connection

Fig.116
3
5.5.6

Mounting the indoor unit

124
Unit LSGT25-S
0.27 - 0.50
2
m
0.18 - 0.33
2
m
1. Position the mounting bracket on the wall.
2. Make sure that the mounting bracket is level.
3. Determine the position of the holes.
4. Drill holes in the wall for the mounting bracket.
5. Secure the mounting bracket to the wall.
6. Use a spirit level to make sure that the mounting bracket stays
horizontal and is perpendicular to the vertical direction.
If installed incorrectly, there may be water leakage from the indoor unit
when the air conditioner is operating in cooling mode.
MW-6020019-01
1. Take out the refrigerant pipes connection.
2. Secure condensate pipe, refrigerant pipes and electric cables together
using plastic cable ties.
3. Wrap all pipes and cables with tape to prevent condensation.
MW-6020016-01
It is possible to install the indoor unit using the existing side pre-shearing
or lead the pipes behind the unit. The wiring, the drain, and the refrigerant
connections are fully suited for connection on either side of the unit.
LSGT35-S
LSGT50-S
0.34 - 0.60
1.55 - 2.83
0.23 - 0.40
1.04 - 1.89
See also
Additional refrigerant charge, page 129
Caution
The wall must be solid and suitable to support 20 kg.
LSGT70-S
1.96 - 3.38
1.31 - 2.26
7798815 - v04 - 07122022