4.3.2 Lubrication cycle
Lubrication cycle set value is displayed as hours and minutes. Decimal point is used to
separate hours and minutes. Decimal point of the set value can be moved as follows.
1.
Select the code for the setting to be changed on the display with
2.
Press SET –button.
3.
Set the desired value with
4.
Press
5.
The decimal point starts to blink.
6.
Move the decimal point to the desired location with
7.
The set value is saved in the memory with SET –button.
5 TECHNICAL SPECIFICATION
5.1 Technical specifications
Quantity
t
U
in
Time settings
Lubrication cycle can be set within 0 min - 999 h.
Maximum pressurization time can be set within 0 s - 999 s.
All time settings are password-protected.
5.2 Symbols
IF-103
IF:
103:
HUIF1BEN.doc
and
–button.
Range
-40...+80
8
45 x 140 x 17
(w x h x d)
Polycarbonate
IP67
Abbreviation
IF
103
MULTILUBE
IF-103
–buttons.
-button.
Unit
Description
°C
Operation temperature
V
Supply voltage from pumping unit circuit board
mm
Dimensions
Material, casing
Protection classification
Description
InterFace
model
8 (8)
-button.
16.06.2004 Rev. 1B