Display - SAFEMATIC IF-103 User Interface Description

Multilube
Table of Contents

Advertisement

2.3 Display

User interface has a display of 3 characters and 3 decimal points.
The display shows time and in pressure transmitter operation also pressure.
Time display
Lubrication cycle set value and elapsed interval are shown on the display as hours and
minutes. Decimal point is used to separate hours and minutes.
Time displayed
0 min -59 min
1 h – 9 h 59 min
10 h -99 h 50 min
100 h – 999 h
Set value for maximum pressurization time and elapsed pressurization time are shown on the
display as seconds without the decimal point.
HUIF1BEN.doc
MULTILUBE
IF-103
Display format
Example
H.MM
12 min = 0.12
H.MM
1 h 20 min = 1.20
HH.M
12 h 50 min = 12.5
HHH.
120 h = 120.
2 (8)
16.06.2004 Rev. 1B