USER INTERFACE IF-103
1 GENERAL DESCRIPTION
IF-103 is a user interface for MultiLube lubrication system.
Lubrication programming, alarm resetting and lubrication event monitoring can be performed
with the user interface.
2 DESIGN
Note
The IF-103 user interface includes a display (pos.1), LED-signals for lubrication lines and
pressurization (pos.2), browsing buttons (pos.3) and setting/function button (SET) (pos.4).
2.1 LED-signals
LED-signal
1
2
P
2.2 Buttons
Button
SET
When a button is pressed, all green LED-signals are lit for a moment. This indicates that
information, that a button has been pressed, has been transmitted forward.
HUIF1BEN.doc
Numbers in brackets are part numbers of drawing 461777.
Description
Green LED-signal is lit, when main line 1 is pressurized.
Green LED-signal is lit during interval, when main line 1 has been pressurized
last.
Red LED-signal is blinking, when main line 1 is in pressure alarm mode.
Green LED-signal is lit, when main line 2 is pressurized.
Green LED-signal is lit during interval, when main line 2 has been pressurized
last.
Red LED-signal is blinking, when main line 2 is in pressure alarm mode.
Green LED-signal is lit, when pressurization phase is in progress.
Red LED-signal is blinking, when the pumping unit is in low level alarm mode.
Description
In normal operation mode, the button is used to browse set values on the
display.
In setting mode, the button is used to change the value on the display.
In normal operation mode, the button is used to browse line pressure displays.
In setting mode, the button is used to move to the next character of the
display.
When browsing the set values, the button is used to return to normal mode.
In normal mode, the button is used to start extra lubrication, to stop
pressurization or reset an alarm.
In setting mode, the button is used to save the value that has been changed.
When browsing the set values, the button is used to go to setting mode.
MULTILUBE
IF-103
1 (8)
16.06.2004 Rev. 1B