Page 1
THESE INSTRUCTIONS CAUTION: To reduce risk of personal injury, use only with mounting assembly models 007180, 007262, 009182, 007265, and 008001 manufactured by Big Fans. TECHNICAL SPECIFICATIONS AirEye 100–120 VAC, 1Ф, 50/60 Hz 100 V 115 V 120 V Motor...
PARTS AND HARDWARE Hinge Pin Eyelets Rear Guard Harmonics Filter**** Front Guard Blade Assembly (4) Motor Thru- Bolts (4) Flange (2) Set Nuts** Screws* Main Mounting Hardware Angle Adjustment Hardware (4) Keyhole Mounting Slots Blade Assembly Retainer*** *Pre-mounted to blade assembly. (4) Safety Hinge Pins **Pre-mounted to motor thru-bolts.
3. BLADE ASSEMBLY Ensure blade assembly is fully seated onto shoulder of shaft and set screws are aligned to fl ats of shaft. 5/32" (4 mm) 20 ft·lb (27.1 N·m) Install if included.
5. SAFETY CABLE Do not attach safety cable to fan mount under any circumstances. 6. HARMONICS FILTER (SELECT REGIONS ONLY) Install if included with your fan.
Page 7
ELECTRICAL CONNECTIONS: FAN ONLY Controller or Automation and Multi-Fan Kit Power Cord ELECTRICAL CONNECTIONS: FAN WITH OCCUPANCY SENSOR Occupancy Sensor Controller or Automation and Multi-Fan Kit Power Cord...
Page 8
ELECTRICAL CONNECTIONS: FAN WITH HARMONICS FILTER Harmonics Filter Power Cord Controller or Automation and Multi-Fan Kit ELECTRICAL CONNECTIONS: FAN WITH OCCUPANCY SENSOR AND HARMONICS FILTER Harmonics Filter Power Cord Occupancy Sensor Controller or Automation and Multi-Fan Kit Conforms to UL 507: Electric Fans Certifi...
Need help?
Do you have a question about the AirEye and is the answer not in the manual?
Questions and answers