4. Press
to stop operation.
Result:
disappears from the LCD. The operation lamp
goes off.

4-3-2 Airflow rate

1. Press
to choose:
5 airflow rate levels, from " " to " "
Automatic operation
Indoor unit quiet operation. When the airflow is set
to "
", the noise from the unit will be reduced.
Note: When using drying operation mode, you CANNOT adjust
the airflow rate setting.
To adjust the airflow rate
1. Press
to change the airflow setting as follows:

4-3-3 Airflow direction

When. Adjust the airflow direction as desired.
What. The system directs the airflow differently, depending
on the user selection (swinging or fixed position). It does so by
moving horizontal blades (flaps) or vertical blades (louvres).
Setting
Moves up and down.
Vertical automatic
swing
Moves from side to side.
Horizontal
automatic swing
Moves simultaneously up and down
+
3-D airflow
and from side to side
direction
[—]
Stays in a fixed position.
CAUTION
• ALWAYS use a remote controller to adjust the position of the
flaps and louvres. When the flaps and louvres are swinging
and you move them forcibly by hand, the mechanism will
break.
• Be careful when adjusting the flaps and louvres. Inside the
air outlet, a fan is rotating at high speed.
Note: The movable range of the flap varies according to the
operation mode. The flap will stop at the upper position when
the airflow rate is changed to low during the up and down swing
setting.
b
a
a Flap range in cooling or drying operation
b Flap range in heating or fan only operation
Airflow direction
To adjust vertical airflow direction
1. Press
.
Result:
appears on the LCD. The flaps (horizontal
blades) will begin to swing.
2. To use fixed position, press
the desired position.
Result:
disappears from the LCD. The flaps will stop
moving.
To adjust horizontal airflow direction
1. Press
.
Result:
appears on the LCD. The louvres (vertical
blades) will begin to swing.
2. To use fixed position, press
the desired position.
Result:
disappears from the LCD. The flaps will stop
moving.
To use 3-D airflow direction
1. Press
and
Result:
and
appear on the LCD. The flaps (horizontal
blades) and louvres (vertical blades) will begin to swing.
2. To use fixed position, press
flaps and louvres reach the desired position.
Result:
and
disappear from the LCD. The flaps
and the louvres will stop moving.

4-3-4 Comfort airflow and Intelligent eye operation

You can use Comfort and Intelligent eye operation separately,
or combine them.
Comfort airflow operation
The unit will automatically change the direction of the airflow to
heat up or cool down the room more effectively. Direct airflow
from the unit will be less noticeable.
a
b
c
a Flap position in cooling and dry operation
b Flap range in heating operation (vertical airflow ON)
c Flap position in heating operation (vertical airflow OFF)
In cooling and drying
The airflow direction will change to spread the air along the ceiling.
Comfort airflow ON
when the flaps reach
when the louvres reach
.
and
when the
Comfort airflow OFF