  • Page 1 LMW-100 v1.00 18.05.2022...
  • Page 2: Table Of Contents

    6 Troubleshooting ............38 7 Battery replacement ..........39 8 Cleaning and maintenance ........39 9 Storage ............... 39 10 Dismantling and utilization ........40 11 Technical data ............41 12 Standard accessories ..........42 13 Manufacturer .............. 42 LMW-100 – USER MANUAL...
  • Page 3: Introduction

    Introduction Thank you for purchasing the LMW-100 distance meter. The device allows user to measure distances with one push of a button. The backlight LCD and handy buttons combine for convenient, er- gonomic operation. Proper use and care of this meter will provide years of reliable service.
  • Page 4: Safety

    Repairs must be realised solely by an authorised service work- shop. WARNING LASER RADIATION DO NOT STARE INTO THE BEAM OF THE LASER DIODE ---------------------------------------------------------------- Wavelength 630-670 nm Max. output power <1 mW Class 2 laser product LMW-100 – USER MANUAL...
  • Page 5: Functional Description

    Functional description Display LMW-100 – USER MANUAL...
  • Page 6 Determining the distance with 3 measurements Single mode measurements Battery status Memory cell number Continuous measurements MIN – minimum distance MAX – maximum distance Error indicator Additional value reading field Additional value reading field Main value reading field LMW-100 – USER MANUAL...
  • Page 7: Buttons

    Surface / volume measurement Indirect measurement 1 / indirect measurement 2 Measurement mode: single / continuous / extreme values "+" button: add another result to the current one "–" button: subtract another result from the current one LMW-100 – USER MANUAL...
  • Page 8: Attaching The Strap

    Entering the memory Changing the measurement reference point Display backlight (press briefly) Changing the measurement unit (press and hold) Delete measurement result (press briefly) Disable the function (press and hold) Attaching the strap LMW-100 – USER MANUAL...
  • Page 9: Measurements

    (e.g. glass), the measurement result may be inaccurate due to scattering or deflection of the laser beam.  If the target is a non-reflective object or an object with a dark surface, the measuring time may be extended. LMW-100 – USER MANUAL...
  • Page 10: Single Mode Measurements

    Continuous measurements  Aim the meter at the surface to which the distance is to be measured.  Press and hold to enable continuous measurements.  To stop continuous mode, briefly press LMW-100 – USER MANUAL...
  • Page 11: Special Features

    The current reading appears at the bottom of the display.  To end the measurement, briefly press . Alterna- tively, the measurements will be stopped when the instrument records 500 measurements.  To switch to single measurement mode, briefly press LMW-100 – USER MANUAL...
  • Page 12: Summing Up The Results

    The main result will be displayed at the bot- tom of the screen.  To clear the last displayed result, press briefly . To disa- ble the function, clear all results and press briefly ► ► ► ► LMW-100 – USER MANUAL...
  • Page 13: Volume Measurement

    The main result will be displayed at the bottom of the screen.  To clear the last displayed result, press briefly . To disa- ble the function, clear all results and press briefly ► ► ► ► ► ► ► LMW-100 – USER MANUAL...
  • Page 14: Determining The Distance With 2 Measurements

    The main result will be displayed at the bottom of the screen.  To clear the last displayed result, press briefly . To disa- ble the function, clear all results and press briefly ▼ ▼ ▼ ▼ LMW-100 – USER MANUAL...
  • Page 15: Determining The Distance With 3 Measurements

    3 in the centre of the screen. The main result will be dis- played at the bottom of the screen.  To clear the last displayed result, press briefly . To disable the function, clear all results and press briefly ▼ ▼ ▼ ▼ ▼ LMW-100 – USER MANUAL...
  • Page 16: Memory Of Measurement Results

    Meter temperature is too high. Cool the meter. Meter temperature is too low. Warm up the meter. Switch the meter off and on several times. Hardware error. If the error persists, contact the service center. LMW-100 – USER MANUAL...
  • Page 17: Battery Replacement

     Make sure the meter and its accessories are dry.  In the case the meter is to be stored for a prolonged period of time, the batteries must be removed from the device. LMW-100 – USER MANUAL...
  • Page 18: Dismantling And Utilization

    Before the equipment is sent to a collection point, do not dis- mantle any elements. Observe the local regulations concerning disposal of packages, worn-out batteries and accumulators. LMW-100 – USER MANUAL...
  • Page 19: Technical Data

    10 m (33 ft). In unfavourable conditions, such as intense sunlight, a poorly re- flecting surface, or significant temperature fluctuations, the deviation in accuracy over a distance of more than 10 m (33 ft) may increase by ± 0.15 mm/m (± 0.0018”/ft). LMW-100 – USER MANUAL...
  • Page 20: Standard Accessories

    The current list of accessories can be found on the manufacturer's website. 13 Manufacturer The provider of guarantee and post-guarantee services is: SONEL S.A. Wokulskiego 11 58-100 Świdnica Poland Tel: +48 74 858 38 60 Fax: +48 74 858 38 09 LMW-100 – USER MANUAL...