 Position Offset 
This value is added to or subtracted from position values in a program while it is running. It is
used to absorb any deviation when the same teaching data is being run on several Electro
Presses. It does not change the teaching data itself. The offset setting affects all programs.
 
 
 
 
 Read Load #1 to 7, Load Calibration Amount #1 to 7
The Read Load amounts and Load Calibration Amounts are settings used to calibration load
amounts. Up to seven points can be set. Three points have been registered as default settings.
If these amounts are consistent with those in the "Load Calibration Values List", then there is no
problem.
However, if there is a considerable difference between the two, it is necessary to reenter
the load calibration value. 
 
 
 
 
 Position Adjustment Amount #1 to 7, Ref Load #1 to 7 
These settings are used to calibrate the strain that occurs when load is applied. Up to seven
points can be set. Two points (one is when zero load is applied and the other is when a load is
applied) have been registered as default. (These points have not been registered for the unit
type.)
If "Absolute Position Adjust Y/N (System settings)" is set to "Enable", the strain will be calculated
from this value. 
 
 
 
 
 Load Offset 
This value is added to or subtracted from the load values.
Without applying load, select "Load Offset" from "Adjustment" in the maintenance mode menu
( MODE key) and press the [ENTR] key to fix the default value. The offset amount is set so
that 0 is displayed when no load is applied. In this way, when power is turned on load reset is
executed manually.
This setting does not change teaching data. The offset setting effects all programs.    
 
Maintenance
6
Electro Press JP Series 4 