Adjustment; Adjustable Value List - Janome JP-104 Operation Manual

Electro press
Hide thumbs Also See for JP-104:
Table of Contents

Advertisement

 

4. ADJUSTMENT

 

4-1 Adjustable Value List

 
To confirm that values such as the calibration amount are normal, refer to the "Adjustable Value
List." The "Adjustable Value List" may cover up to two pages depending on the setting.
Press the [ESC] key to return to the previous page. 
 
 
● 
Press the [MODE] key to display the
Maintenance Mode Menu.
 
Select "Adjustment" and press the [ENTR]
● 
key.
 
 
 
 
 
 
 
 
 
 
Select "Adjustable Value List" and press
● 
the [ENTR] key.
 
 
 
 
 
 
 
 
 
 
 
 
 
An "Adjustable Value List" like the one to
● 
the right is displayed.
 
The Adjustable Value List may cover two
pages depending on the setting.
Use the [CURSOR] and [CURSOR] keys
to move between pages. 
 
 
 
 
Maintenance
Maintenance Mode Menu
Adjustment
Version Information
Setting Information
Diagnostic Mode
Mechanical Adjustment Mode
 
 
 
 
 
 
 
 
Adjustment
Adjustable Value List
Position Offset
Load Calibration
Clear Load Calibration
Position Adjustment
Clear Position Adjustment
Measure of Strain
Load CalAmnt Offset
Load Calibration (Number)
 
 
 
 
Position Offset
Read Load #1
Load CalAmnt #1
Read Load #2
Load CalAmnt #2
Read Load #3
Load CalAmnt #3
Pos'nAdjAmnt #1
Ref Load #1
Pos'nAdjAmnt #2
Ref Load #2
Load Offset
 
<Adjustable Value List Screen>
5
0.000 mm
449 N
0 N
938 N
487 N
1427 N
961 N
0.000 mm
0 N
0.221 mm
8000 N
447 N 
Electro Press JP Series 4 

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents