Milwaukee MW12 User Manual

Milwaukee MW12 User Manual

Digital phosphate low range mini photometer
Hide thumbs Also See for MW12:

Advertisement

Quick Links

SPECIFICATIONS

Range
0.00 to 2.50 ppm
Resolution
0.01 ppm
±0.04 ppm ±4% of reading
Accuracy
@ 25 °C
Typical EMC Dev. ±0.01 ppm
Light Emitting Diode
Light Source
@ 525 nm
Light Detector
Silicon Photocell
Adaptation of the Standard
Methods for the Examination
of Water and Wastewater,
20
edition, Ascorbic Acid
th
Method
method. The reaction
between phosphate and the
reagent causes a blue tint in
the sample.
0 to 50°C (32 to 122 °F)
Environment
max. 95% RH non-condensing
Battery Type
1 x 1.5V AAA
After 3 minutes of non-use
Auto-Shut Off
and 2 minutes after reading
81.5 x 61.0 x 37.5 mm
Dimensions
(3.2 x 2.4 x 1.5")
Weight
64 g (2.25 oz.)

OPTIONAL ACCESSORIES

Reagent Sets
Phosphate powder reagent,
MI512-25
25 pcs.
Other Accessories
MI0011
Glass cuvettes (2 pcs.)
MI0013
Stoppers for cuvettes (2 pcs.)

CERTIFICATION

Milwaukee Instruments conform to
the CE European Directives.
Disposal of Electrical & Electronic
Equipment. Do not treat this product
as household waste. Hand it over
to the appropriate collection point
for the recycling of electrical and
electronic equipment.
Disposal of waste batteries. This product
contains batteries. Do not dispose of them with
other household waste. Hand them over to the
appropriate collection point for recycling.
Please note: proper product and battery disposal
prevents
potential
negative
for human health and the environment. For
detailed
information,
contact
household waste disposal service or go to
www.milwaukeeinstruments.com (USA & CAN)
or www.milwaukeeinst.com.

RECOMMENDATION

Before using this product, make sure it is entirely
suitable for your specific application and for the
environment in which it is used. Any modification
introduced by the user to the supplied equipment
may compromise the meter's performance. For
your and the meter's safety do not use or store
the meter in hazardous environment. To avoid
damage or burn, do not perform any measurement
in microwave ovens.

WARRANTY

This instrument is warranted against defects
in materials and manufacturing for a period of
2 years from the date of purchase. This warranty
is limited to repair or free of charge replacement if
the instrument cannot be repaired. Damage due to
accidents, misuse, tampering or lack of prescribed
maintenance is not covered by warranty. If
service is required, contact your local Milwaukee
Instruments Technical Service. If the repair is not
covered by the warranty, you will be notified of
the charges incurred. When shipping any meter,
make sure it is properly packaged for complete
protection.
Milwaukee Instruments reserves the right to
make improvements in design, construction and
appearance of its products without advance notice.
ISTMW12 07/20
USER MANUAL
Phosphate Low Range
Mini Photometer
consequences
your
local
milwaukeeinstruments.com (USA & CAN)
SATISFACTION
GUARANTEED
MW12
Digital
milwaukeeinst.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MW12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Milwaukee MW12

  • Page 1 Damage due to accidents, misuse, tampering or lack of prescribed Reagent Sets maintenance is not covered by warranty. If service is required, contact your local Milwaukee Phosphate powder reagent, MI512-25 Instruments Technical Service. If the repair is not 25 pcs.
  • Page 2 5000 measurements, depending Each MW12 meter is supplied complete with: on the light level. When the battery capacity is under 10 % “bAt” appears on the LCD at y Two Sample Cuvettes and Caps start-up.

Table of Contents