Indoor unit
The flap does not start swinging
immediately.
• The air conditioner is adjusting the position of the flap.
The flap will start moving soon.
The air conditioner stops generating
airflow during HEAT operation.
• Once the set temperature is reached, the airflow rate is
reduced and operation stopped in order to avoid
generating a cool airflow. Operation will resume
automatically when the indoor temperature falls.
HEAT operation stops suddenly and
a flowing sound is heard.
• The outdoor unit is defrosting. HEAT operation starts
after the frost on the outdoor unit has been removed.
This can take about 4 to 12 minutes.
Operation does not start soon.
„ When
was pressed soon after operation
was stopped.
„ When the mode was reselected.
• This is to protect the air conditioner.
You should wait for about 3 minutes.
Outdoor unit
The outdoor unit emits water or steam.
„ In HEAT operation
• The frost on the outdoor unit melts into water or steam when the air
conditioner is in defrosting operation.
„ In COOL or DRY operation
• Moisture in the air condenses into water on the cool surface of the outdoor
unit piping and drips.
Different sounds are heard.
„ A sound like flowing water
• This sound is generated because the refrigerant in
• This is a pumping sound of the water in the air conditioner
„ Blowing sound
• This sound is generated when the flow of the
„ Ticking sound
• This sound is generated when the cabinet and
„ Whistling sound
• This sound is generated when refrigerant flows
„ Clicking sound during operation or idle time
• This sound is generated when the refrigerant control
„ Clopping sound
• This sound is heard from the inside of the air
„ Rotating machinery causes sound
• Sound is heard when the vertical swing flaps and
• When the air conditioner is operating in a quiet environment
* The appearance of the outdoor unit may differ from some models.
When the Need Arises
the air conditioner is flowing.
and can be heard when the water is pumped out from the
air conditioner during COOL or DRY operation.
refrigerant in the air conditioner is switched over.
frame of the air conditioner slightly expand or shrink
as a result of temperature changes.
during defrosting operation.
valves or the electrical parts operate.
conditioner when the exhaust fan is activated while
the room doors are closed. Open the window or turn
off the exhaust fan.
the horizontal swing flaps move.
and the airflow rate of the indoor unit is set to Quiet Mode or
Low Mode, the motion of the swing flaps may cause sound.