Midea MPF10CR71 User Manual page 9

Hide thumbs Also See for MPF10CR71:
Table of Contents

Advertisement

Swing
Sleep
Control
Mode
Mode button
Selects the appropriate operating mode.
Each time you press the button, a mode
is selected in a sequence that goes
from AUTO, COOL, DRY, FAN and HEAT
(cooling only models without). The mode
indicator light illuminates under the
different mode settings.
Up (+) and Down (-) buttons
Used to adjust (increasing/decreasing)
temperature settings in 1°C/1°F
increments in a range of 17°C/62°F to
30°C/86°F or the TIMER setting in a
range of 0 ~ 24hrs.
NOTE
The control is capable of displaying
temperature in degrees Fahrenheit or
degrees Celsius. To convert from one
to the other, press and hold the Up
and Down buttons at the same time
for 3 seconds.
Power button
Power switch on/off.
 Page 8 
(3s activate ion)
Auto
Fan
Timer
Speed
LED Display
Mode
Up (+) and
Selector
Down (-) Control
LED display
Shows the set temperature in °C or °F
and the Auto-timer settings. While on
DRY and FAN modes, it shows the room
temperature.
Shows Error codes and protection code:
E1 - Room temperature sensor error.
E2 - Evaporator temperature sensor error.
E3 - Condenser temperature sensor error
(on some models).
E4 - Display panel communication error.
E7 - Zero-crossing malfunction.
P1 - Bottom tray is full -- Connect the
drain hose and drain the collected
water away. If protection repeats, call
for service.
NOTE
When one of the above malfunctions
occurs, turn off the unit, and check
for any obstructions. Restart the unit,
if the malfunction is still present, turn
off the unit and unplug the power
cord. Contact the manufacturer or its
service agents or a similar qualified
person for service.