INSTRUCTION MANUAL
DC CURRENT OUTPUT MODULE, 2 points
(MECHATROLINK-I / -II)
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
DC current output module............................................... (1)
■ MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
SEN TRONIC
POINTS OF CAUTION
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and output signal for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 30 to 90% RH in
order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
056 222 38 18
mailbox@sentronic.com
AG
R7ML-YS2
MODEL
24V DC rating: 24V ±10%, approx. 130mA
www.sentronic.com
R7ML-YS2
EM-7805-E Rev.2
P. 1 / 10

Advertisement

loading

Summary of Contents for M-system R7ML-YS2-R

  • Page 1 (MECHATROLINK-I / -II) BEFORE USE ..POINTS OF CAUTION Thank you for choosing M-System. Before use, please check ■ POWER INPUT RATING & OPERATIONAL RANGE contents of the package you received as outlined below. • Locate the power input rating marked on the product and...
  • Page 2: Component Identification

    R7ML-YS2 COMPONENT IDENTIFICATION ■ FRONT VIEW MECHATROLINK Setting Rotary SW Operating Mode Setting DIP SW (SW1) Station Address Setting PC Configurator Jack Rotary SW Status Indicator LED MECHATROLINK Connector CNFG. STATION ADD. B. RATE Power Supply Terminals Output Terminals ■ LEFT SIDE VIEW MECHATROLINK Connector EM-7805-E Rev.2 P.
  • Page 3 R7ML-YS2 ■ STATUS INDICATOR LED ■ PC CONFIGURATOR JACK Analog output modules are equipped with the PC Configu- COLOR FUNCTION rator Jack. Green Turns on when the internal 5V is supplied The PC Configurator is used to set the following parameters normally.
  • Page 4: External Dimensions

    R7ML-YS2 EXTERNAL DIMENSIONS unit: mm (inch) 3 (.12) 115 (4.53) 17 (.66) 54 (2.13) DIN RAIL 35mm wide 30 (1.18) [5 (.20)] 75 (2.95) 6 (.24) 6 (.24) 10–M3 SCREW 7–M3 SCREW TERMINALS for POWER TERMINALS for OUTPUT CONNECTION DIAGRAM Connect the unit as in the diagram below.
  • Page 5: Wiring Instructions

    R7ML-YS2 WIRING INSTRUCTIONS ■ SCREW TERMINAL Torque: 0.5 N·m ■ SOLDERLESS TERMINAL mm (inch) Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Solder- less terminal: Applicable wire size: 0.25 to 1.65 mm (AWG 22 to 16) Recommended manufacturer: Japan Solderless Terminal MFG.
  • Page 6 R7ML-YS2 MECHATROLINK RELATED COMMANDS ■ MECHATROLINK DATA LINK LAYER COMMAND DESCRIPTIONS The R7ML, Intelligent I/O, performs the connection-type communications according to MECHATROLINK protocol. The following tables explain Data Link Layer Commands supported by the R7ML. • MDS Command (04H) Data Format Byte COMMAND RESPONSE...
  • Page 7 R7ML-YS2 ■ MECHATROLINK APPLICATION LAYER COMMAND DESCRIPTIONS The following tables explain Application Layer Commands supported by the R7ML. • NOP Command (00H) Data Format Byte COMMAND RESPONSE REMARKS CDRW (03H) ACK (01H) Cyclic Data Read/Write (CDRW) Command: Link transmission Acknowledge (ACK): Positive response to CDRW NOP (00H) NOP (00H) No Operation (NOP) Command: Nothing is performed.
  • Page 8 R7ML-YS2 • CONNECT Command (0EH) Data Format Byte COMMAND RESPONSE REMARKS CDRW (03H) ACK (01H) Cyclic Data Read/Write (CDRW) Command: Link transmission Acknowledge (ACK): Positive response to CDRW CONNECT CONNECT Establish Connection (CONNECT) Command: Requests to establish (0EH) (0EH) connection to MECHATROLINK ALARM Error code: See “MECHATROLINK DATA DESCRIPTIONS”...
  • Page 9 R7ML-YS2 • DATA_RWA Command (50H) Data Format Byte COMMAND RESPONSE REMARKS CDRW (03H) ACK (01H) Cyclic Data Read/Write (CDRW) Command: Link transmission Acknowledge (ACK): Positive response to CDRW DATA_RWA DATA_RWA Data Read/Write_A (DATA_RWA) Command: Refreshes I/O data (50H) (50H) ALARM Error code: See “MECHATROLINK DATA DESCRIPTIONS” STATUS1 Status code: See “MECHATROLINK DATA DESCRIPTIONS”...
  • Page 10 R7ML-YS2 • Output Data Output data to be sent from the master to the slave are set in the command. Unused with all input modules. DESCRIPTION REMARKS CH1 OUT CH1 data, low 8 bits R7ML-DC16x: Bit 0 through 7 data are set. CH1 OUT HI CH1 data, high 8 bits R7ML-DC16x: Bit 8 through 15 data are set.

This manual is also suitable for:

R7ml-ys2