INSTRUCTION MANUAL
STRAIN GAUGE INPUT MODULE
(MECHATROLINK-I / -II, with monitor output, 2 points, isolated)
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Strain gauge input module .......................................... (1)
■ MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EU DIRECTIVE
• Use MECHATROLINK-II network cable with core (Yasu-
kawa Controls Model JEPEC-W6003-x-E) or equivalent
for the network.
• Be sure to earth FG terminal.
• The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 130mA
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ven-
tilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 30 to 90% RH in
order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp
R7ML-LC2
R7ML-LC2
MODEL
EM-7805-AX
P. 1 / 10

Advertisement

loading

Summary of Contents for M-system R7ML-LC2

  • Page 1 10 minutes is required for satisfying complete performance described in the data sheet. EM-7805-AX P. 1 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...
  • Page 2: Input

    10 11 12 13 15 16 17 18 Power Supply Terminals I/O Terminals LEFT SIDE VIEW MECHATROLINK Connector EM-7805-AX P. 2 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...
  • Page 3: Exc0

    SW1-5 SW1-6 SW1-7 Averaging 2 samples (*) 4 samples 8 samples 16 samples 32 samples 64 samples 128 samples 256 samples 512 samples 1024 samples EM-7805-AX P. 3 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...
  • Page 4 * MECHATROLINK connectors are internally connected. The network cable can be connected to either one. EM-7805-AX P. 4 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...
  • Page 5: Sld0

    Distance between stations: 50 cm min. Transmission media: MECHATROLINK cable (Model JEPMC-W6003-x-E, Yaskawa Controls Co., Ltd.) Max. number of slaves: 30 (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit) Transmission cycle: 0.5 msec., 1 msec., 1.5 msec., 2 msec., 4 msec., 8 msec. Data length: 17 bytes / 32 bytes selectable (Must choose identical data size for all stations on one network) EM-7805-AX P. 5 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...
  • Page 6: Em-7805-Ax P

    Command Ready Bit 1 : Command can be accepted (ready), 0 : Command cannot be accepted (busy) 3 – 7 Unused ---- EM-7805-AX P. 6 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...
  • Page 7 Discrete input data of extension module high 8 "0" for EA8 and EC8x module high 8 bit bit or echo back of set value at command area 15 – 31 Unused EM-7805-AX P. 7 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...
  • Page 8 8 bit bit or echo back of set value at command area 15 – 31 Unused EM-7805-AX P. 8 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...
  • Page 9 Input 1 Mode setting Input 1 Reset offset Input 1 Below range Input 1 Within range Input 1 Over range EM-7805-AX P. 9 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...
  • Page 10 ■ INPUT OVER RANGE (Input only) “1” is to be set when input is 101.0% or more. EM-7805-AX P. 10 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81 ( 6 ) 6659-8201 Fax: +81 ( 6 ) 6659-8510 E-mail: info@m-system.co.jp...