Haier GE NF96DS Installation Instructions Manual page 47

Warm air gas furnace downflow air discharge direct vent & non-direct vent
Hide thumbs Also See for GE NF96DS:
Table of Contents

Advertisement

NF96D090S4C Performance (Less Filter)
External
Static
High
Pressure
cfm
in. w.c.
0.00
1760
0.10
1730
0.20
1700
0.30
1670
0.40
1640
0.50
1590
0.60
1530
0.70
1445
0.80
1350
NOTE: All air data is measured external to unit without filter (not furnished - field provided)
Model
045
070
090
Model
All Models
Factory Setting
507769-05G / 31-5000656
Air Volume / Watts at Different Blower Speeds
Medium-High
watts
cfm
watts
435
1555
280
445
1515
300
455
1475
315
465
1445
330
480
1410
340
485
1380
345
465
1340
360
450
1315
370
420
1280
375
Allowable Heating Speeds
Red
Yellow
Allowed
Factory Setting
Allowed
Factory Setting
Allowed
Factory Setting
Allowable Circulation Speeds
Red
Yellow
Not Allowed
Medium
cfm
watts
1405
230
1375
240
1350
250
1310
265
1265
275
1225
285
1195
295
1150
305
1115
315
Blue
Allowed
Allowed
Allowed
Table 21.
Blue
Not Allowed
Table 22.
Issue 2223
Medium-Low
cfm
watts
cfm
1315
175
1190
1280
190
1150
1245
205
1115
1200
220
1070
1160
230
1025
1125
235
985
1085
245
945
1065
255
895
1015
265
860
Brown
Not Allowed
Not Allowed
Allowed
Brown
Not Allowed
Low
watts
135
145
155
165
175
185
195
200
210
Black
Not Allowed
Not Allowed
Not Allowed
Black
Not Allowed
Page 47 of 55