CAUTION
1" min. 2" max. above
condensate drain.
A separate drain line must be run to the drain from the
condensate trap to ensure proper drainage and pressure
switch operation. DO NOT connect the condensate trap
drain into the drain line from the evaporator coil.
FurnaceCondensate
Drain Connection
Optional
IMPORTANT
When combining the furnace and evaporator coil
drains together, the A/C condensate drain outlet must
be vented to relieve pressure in order for the furnace
pressure switch to operate properly.
Figure 44. Condensate Trap with Optional Overflow
Switch