Gas Flow (Approximate)
Gas Meter Clocking Chart
Seconds for One Revolution
Natural
Capacity
1 cu ft
Dial
-045
80
-070
55
-090
41
Natural - 1000 btu/cu ft
Table 15.
Proper Combustion
Furnace should operate minimum 15 minutes with correct
manifold pressure and gas flow rate before checking
combustion. Take combustion sample beyond the flue outlet
and compare to Table 16.
Capacity
CO
All
7.2 - 8.2
The maximum carbon monoxide reading should not exceed
100 ppm.
Table 16.
Capacity
All
* Conversion requires installation of a gas valve regulator spring, which is provided with the gas conversion kit.
† LP kits include low line pressure switch.
Capacity
045
070
090
Pressure switch is factory set. No adjustment necessary. All models use the factory-installed pressure switch from 0-4,500 feet (0-
1,370 m).
31-5000729 Rev. 0
LP
2 cu ft
1 cu ft
2 cu ft
Dial
Dial
Dial
160
200
400
110
136
272
82
102
204
LP - 2500 btu/cu ft
% for Nat
CO
% for L.P.
2
2
8.6 - 9.6
0 - 7,500 ft
(0 - 2,286 m)
Natural to LP/Propane
11K50†
Table 17. Burner Orifice Conversion Kits at Varying Altitudes
0 - 4,500 ft.
(0 - 1,373 m)
No Change
Table 18. Pressure Switch Requirements at Varying Altitudes
High Altitude
NOTE: In Canada, certification for installations at elevations
over 4500 feet (1372 m) is the jurisdiction of local authorities.
Units may be installed at altitudes up to 10,000 ft. above
sea level. See Table 14 for de-rate manifold values. Units
installed at altitude of 7501 - 10,000 feet require an orifice
change. Units installed at altitudes of 4501 - 10,000 feet (1373
to 3048 m) require a pressure switch change which can be
ordered separately. Table 17 and Table 18 list conversion kit
and pressure switch requirements at varying altitudes.
The combustion air pressure switch is factory-set and
requires no adjustment.
High Altitude Natural Burner
Orifice Kit
51W01
4,501 - 7,500 ft.
(1,371 - 2,286 m)
11U65
11U70
11U70
Page 45
7,501 - 10,000 ft
(2,286 - 3048m)
High Altitude LP/Propane
Burner Orifice Kit
11K45†
7,501 - 10,000 ft
(2,286 - 3,048 m)
11U66
11U68
10U93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ge nf96d045s3bGe nf96d070s4bGe nf96d090s4c