Haier GE NF96DS Service Manual page 25

96% downflow single stage constant torque motor gas furnace
Hide thumbs Also See for GE NF96DS:
Table of Contents

Advertisement

1-1/2" Pipe
Capacity
Number of 90°
Elbows Used
045
1
10
2
3
4
5
6
n/a
7
8
9
10
NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake
and Exhaust must be same pipe size.
NOTE - Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length
calculation.
Number of 90°
Elbows Used
045
1
35
2
30
3
25
4
20
5
15
6
10
7
8
n/a
9
10
NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake
and Exhaust must be same pipe size.
NOTE - Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length
calculation.
31-5000729 Rev. 0
Maximum Allowable Intake or Exhaust Vent Length in Feet
Concentric Termination at Elevation 0 - 2,000 ft
2" Pipe
Capacity
070
090
045
10
53
48
43
38
33
n/a
n/a
28
23
18
13
n/a
Maximum Allowable Intake or Exhaust Vent Length in Feet
Concentric Termination at Elevation 2,001 - 10,000 ft
2" Pipe
Capacity
070
090
25
15
20
10
15
10
n/a
n/a
2-1/2" Pipe
Capacity
070
090
045
38
22
90
33
17
85
28
12
80
23
75
18
70
13
65
n/a
60
55
50
45
Table 10C.
2-1/2" Pipe
Capacity
030/
070
045
90
63
85
58
80
53
75
48
70
43
65
38
60
33
55
28
50
23
45
18
Table 10D.
Page 25
3" Pipe
Capacity
070
090
045
70
39
111
65
34
106
60
29
101
55
24
96
50
19
91
45
14
86
40
9
81
35
76
30
n/a
71
25
66
3" Pipe
Capacity
030/
090
070
045
39
111
111
34
106
106
29
101
101
24
96
96
19
91
91
14
86
86
9
81
81
76
76
n/a
71
71
66
66
070
090
111
104
106
99
101
94
96
89
91
84
86
79
81
74
76
69
71
64
66
59
090
104
99
94
89
84
79
74
69
64
59