7. Normal operation

In normal operation, LCD screen alternatively shows inverter power and operation status
(see Figure 7.1). The screen can be scrolled manually by pressing the UP/DOWN keys.
Pressing the ENTER key gives access to Main Menu.
Power
01-01-2019
5 sec
UP/DOWN or
Start
auto-scroll
(10 sec)
Status: Generating
01-01-2019
Pressing the
ENTER key
gives access to
the main menu.
Figure 7.1 Operation Overview

7.1 Main Menu

There are four submenus in the Main Menu (see Figure 7.1):

1. Information

2. Settings
3. Advanced Info.
4. Advanced Settings
7.2 Information
The Canadian Solar three Phase Inverter main menu provides access to operational
data and information. The information is displayed by selecting "Information" from the
menu and then by scrolling up or down.
.40.
Pressing the
Main Menu
ESC key
calls back the
previous menu.
Information
110000W
UP/DOWN
12:04
Settings
UP/DOWN
Advanced Info.
UP/DOWN
12:04
Advanced settings
7. Normal operation
Display
Duration
V_DC01: 0000.0A
I_DC01: +000.0A
V_DC: Shows input DC voltage.
...
10 sec
V_DC06: 0000.0A
I_DC: Shows input DC current.
I_DC06: +000.0A
V_A: 000.0V
I_ A:
000.0A
V_A(B,C): Shows the grid's voltage value.
. . .
10 sec
V_C: 000.0V
I_A(B,C): Shows the grid's current value.
I_ C:
000.0A
Status: Shows instant status of the Inverter.
Status: Generating
10 sec
Power: 0000W
Power: Shows instant output power value.
Rea_Power: Shows the reactive power of the inverter.
Rea_Power: 0000Var
10 sec
App_Power: 0000VA
App_Power: Shows the apparent power of the inverter.
Grid Frequency
F_Grid: Shows the grid's frequency value.
10 sec
F_Grid
00.00Hz
Total Energy
Total generated energy value.
10 sec
0000000 kwh
This Month: Total energy generated this month.
This Month: 0000kwh
10 sec
Last Month: 0000kwh
Last Month: Total energy generated last month.
Today: Total energy generated today.
Today:
00.0kwh
10 sec
Yesterday: 00.0kwh
Yesterday: Total energy generated yesterday.
Inverter SN
10 sec
Display series number of the inverter.
00000000000000
Power of EPM.
Export_P:NULL
10 sec
Export_I:NULL
Current of EPM.
Work Mode: Shows current working mode.
Work Mode: NULL
10 sec
DRM NO.:08
DRM NO.: Shows DRM Number.
I_DC01 : Shows input 01 current value.
I_DC01: +05.0A
I_DC02 : Shows input 02 current value.
I_DC02: +04.9A
10 sec
...
...
I_DC12: +05.2A
I_DC12 : Shows input 12 current value.
Table 7.1 Information list