Panasonic CS-A18BTP Service Manual page 36

Table of Contents

Advertisement

15.2. COOLING PERFORMANCE
Model
Cooling capacities are based on conditions below.
CS-A18BTP
1 phase, 50Hz, 240V
Cooling capacity
Indoor temperature 27°C D.B. 19 °C W. B.
5.0 kW
Outdoor temperature 35°C D.B.
Standard air volume 14m
Entering
Temperature Air Entering Condenser (°C D.B.)
Air
25
Temperature
TC
D.B.
W.B.
kW
17
5.13
23
19
5.41
22
5.84
17
5.15
25
19
5.46
22
5.92
17
5.18
27
19
5.51
22
5.99
17
5.25
29
19
5.62
22
6.03
17
5.29
32
19
5.69
22
6.05
3
/min
30
35
40
TC
TC
TC
kW
kW
kW
4.90
4.60
4.30
5.15
4.88
4.56
5.56
5.27
4.97
4.93
4.65
4.34
5.22
4.94
4.60
5.64
5.35
5.03
4.96
4.70
4.37
5.30
5.00
4.65
5.72
5.43
5.09
5.02
4.77
4.43
5.39
5.07
4.71
5.77
5.44
5.13
5.07
4.82
4.46
5.45
5.12
4.75
5.80
5.45
5.15
Entering
Air
Temperature
D.B.
W.B.
17
23
19
22
17
43
25
19
TC
22
kW
17
4.00
27
19
4.24
22
4.66
17
4.04
29
19
4.30
22
4.74
17
4.09
32
19
4.35
22
4.82
4.10
4.41
4.85
4.11
4.46
4.87
TC = Total Cooling Capacity
IPT = Power Consumption
36
Temperature Air Entering Condenser (°C D.B.)
25
30
35
IPT
IPT
IPT
kW
kW
kW
1.52
1.66
1.79
1.57
1.71
1.85
1.60
1.74
1.88
1.54
1.68
1.81
1.61
1.75
1.90
1.65
1.78
1.94
1.56
1.70
1.82
1.66
1.79
1.95
1.70
1.83
1.99
1.61
1.74
1.86
1.72
1.85
1.99
1.80
1.93
2.06
1.65
1.77
1.89
1.76
1.89
2.02
1.87
1.99
2.11
40
43
IPT
IPT
kW
kW
1.93
2.01
1.95
2.07
1.99
2.11
1.95
2.03
2.01
2.13
2.04
2.16
1.96
2.05
2.07
2.18
2.09
2.21
1.98
2.08
2.08
2.19
2.15
2.23
1.99
2.09
2.10
2.20
2.18
2.25