Download Print this page

Hyundai HNHPT206B-A2 Original Instruction Manual page 22

Thermal high-pressure cleaner

Advertisement

Problem resolution:
Before each maintenance and repair, disconnect the power supply before doing any maintenance or repair.
Breakdowns
During start up, the engine does
not start
The high pressure cleaner cannot
be reached
The output pressure undergoes
fluctuations
No detergent
The connection of the hose or
spray lance leaks
The water pump is noisy
Leakage of water pump
Oil leakage
If you encounter other problems, do not hesitate to call the customer service for assistance
Original Instruction manual
Possible reasons
No fuel
Oil level is very low
The choke is not in the right
position
The gas command is not in the right
position
The pressure remains in the cleaner
The diameter of the inlet hose is too
small
The water supply is insufficient
The water inlet is small
Filter clogged water
The black nozzle detergent suction
mounted
Pump inhales air
The water inlet filter is clogged
The nozzle is clogged
spray gun, hose or the lance is
calcified
The detergent suction tube is not
connected properly
Detergent too thick
Detergent filter valve is set to a very
small passage
Filter detergent suction tube is
clogged
Detergent suction hose is damaged
or obstructed
The nozzle is clogged
Fixing parts are loose
Damage or wear of the pipe or spear
Pump inhaling air
Damage or wear of the seal
Damage or wear of seals
19
Solution
Fill the fuel tank
Add oil
Move the starter to "ON"
Move lever gas control to the left
Press the trigger to remove the
remaining air in the pipes
Use a bigger pipe
Check if the hose is twisted, folded
or stuck
Open valve completely
Remove filter, clean with warm
water
Use high pressure nozzle
Stop the machine; hold the trigger,
to completely remove the air in
cleaner.
Remove the filter, clean with
warm water
Blow air or use a needle to remove
the clog
Fill the detergent inlet tube with
white vinegar
Check the connection
Dilute detergent
Adjust the valve to a bigger
passage
Pour warm water in the filter in
order to remove particles
Remove the obstruction or replace
the pipe
Clear tip
Tighten the fixing parts
Replace damaged parts
Put off the machine, press the
trigger to purify the water circuit
cleaner
Ask customer service, to be
replaced with new seals
Ask customer service, to be
replaced with new seals

Advertisement