If the refrigerant leaks during installation, ventilate the
area immediately.
Toxic gas may be produced if the refrigerant comes into
contact with fire.
The temperature of the refrigerant circuit will be high, so
please keep the interconnection cable away from the
copper tube.
After completing the installation work, check that the
refrigerant does not leak.
Toxic gas may be produced if the refrigerant leaks into the
room and comes into contact with a source of fire such as a
fan heater, stove or cooker.
CAUTION
Ground the air conditioner.
Do not connect the ground wire to gas or water pipes,
lightning rods, or a telephone ground wire. Incomplete
grounding may result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in
electric shocks.
Connect the outdoor unit wires, then connect the indoor
unit's wires.
Do not connect the air conditioner with the power source until
the wiring and piping is completed.
When following the instructions in this installation
manual, install drain piping to ensure proper drainage
and insulate piping to prevent condensation.
Improper drain piping may result in water leaks and property
damage.
Install the indoor and outdoor units, power supply wiring
and connecting wires at least 1 m away from televisions
or radios to prevent image interference or noise.
Depending on the radio waves, a distance of 1 m may not be
sufficient to eliminate noise.
The appliance is not intended for use by young children
or the elderly without supervision.
Do not install the air conditioner in the following
locations:
Where there is petroleum.
There is salty air surrounding (near the coast). If this
cannot be avoided, choose an anticorrosive model.
Where there is caustic gas (e.g., sulfide, such as near a
hot spring).
Where the voltage vibrates greatly (in factories).
In buses or cabinets.
In kitchens due to oil vapor.
Where there is a strong electromagnetic wave.
Where there are inflammable materials or gas.
Where acid or alkaline liquid evaporates.
Other special conditions.
The appliance should not be installed in a laundry room.

2. INSTALLATION INFORMATION

To install the unit properly, please read this Installation
Manual.
The air conditioner must be installed by qualified personnel.
When installing the indoor unit or its tubing, follow this
manual as strictly as possible.
If the air conditioner is installed on a metal part of the
building, it must be electrically insulated according to the
relevant standards for electrical appliances.
When all the installation work is completed, please turn on
the power only after it has been thoroughly checked.
Notice will not be given regarding any changes to this
manual due to product improvements.
INSTALLATION ORDER
Select the location;
Install the indoor unit;
Install the outdoor unit;
Install the connecting pipe ;
Connect the drain pipe;
Wiring;
Test operation.

3. ATTACHED FITTINGS

Please check whether all the following fittings have been included.
If there are some spare fittings, please store them carefully.
Name of
Accessories
Installation manual
Hook
Hanging arm
Weak electric cable group
Drainage pipe
Bolt assembly
Copper
Snapring
2
Qty
Outline
Usage
1
(This manual)
2
2
.
1
1
Drainage
4
Use for pipe connection
1
of engineering
installation
Use for fastening the
1
drainage pipe

Advertisement

Table of Contents
loading

Table of Contents