CHECK THE HUMIDIFIER OPERATION

Turn the control knob to the maximum RH setting . Make sure that the
water saddle valve is open and that the humidifier is on . The indoor unit
blower must be running for the humidifier to function . Once humidifier
operation is verified, reduce the Humidifier Control setting to the
recommended inside humidity, depending on the outside temperature .
If using the automatic humidifier control model number
KUAWC0101COR, DO NOT LEAVE IN TEST MODE AS HUMIDIFIER
WILL NOT OPERATE.

ADDITIONAL INFORMATION

Be sure to keep fireplace dampers closed when not in use . They provide
an excellent escape route for heat, as well as humidity .
On occasion, indoor moisture producing activities such as clothes drying,
cooking, showers, etc ., may raise the humidity level higher than it should
be, even though the humidifier is not operating . Telltale indications are
condensation or frost on cold surfaces such as windows, doors, walls,
etc . If such condensation persists for several hours, your home should be
ventilated to dissipate the potentially damaging excess moisture .

MAINTENANCE

WARNING
ELECTRIC SHOCK HAZARD. Disconnect main electrical power
to the humidifier at the circuit breaker and drain the water from
unit before servicing. Hot surface inside.
NOTICE
• Service should be performed by an HVAC technician.
• Use only genuine replacement parts.
- 10 -
INSPECT HUMIDIFIER WHEN SERVICING
• Replace the canister annually and when prompted by the "Service" light
• Clean drain valve and fill valve screen annually
• Replace electrode wires every 3 years or more frequently as needed (see
step 3 of CANISTER REPLACEMENT AND DRAIN VALVE SERVICE)
• Inspect humidifier at approximately 500 hour intervals or several times
during the humidification season .
SERVICE SHUTDOWN PROCEDURE
1 . Press On/Off button to turn humidifier off (see FIGURE 2) .
2 . Allow humidifier to drain .
3 . When the green Drain light (see FIGURE 2) stops flashing, disconnect
main electrical power to humidifier at the circuit breaker .
4 . Allow the unit to cool .
5 . Shut off water supply to unit .
FIGURE 2 – Steam Humidifier
On/Off button
1
and light
Drain light
2
Front panel
3
Side panel
4
Service light
5
CANISTER REPLACEMENT AND DRAIN VALVE SERVICE
Use only genuine replacement part number 8045HUM .
1 . Remove front panel (see FIGURE 2) .
2 . Pull three wires off posts on top of canister (two electrode wires and
one water level probe wire, shown in FIGURE 3A and FIGURE 3B) .
3
4
1
2
5
- 11 -