INTRODUCTION FIGURE 1 – Fill and Drain System and Canister Thank you for your recent steam humidifier purchase . We appreciate Steam your business and are pleased to add your name to our growing list of Outlet customers . You have invested in the highest quality equipment available . Your humidifier will require periodic maintenance to assure continued Fill Cup consistent performance .
INSTALLATION OPTIONS & EFFECT OF OPERATING MODES WATER CHARACTERISTICS When the humidifier is powered and turned on, the “On/Off” light is illuminated green . Your Steam Humidifier can be installed to operate on 120 volts, 208 volts or 240 volts using 11 .5 or 16 .0 amps . The higher the voltage and amperage When the canister is being filled or replenished with water, the “Fill”...
DISPLAY PANEL HUMIDIFIER CONTROL & OPERATING INSTRUCTIONS The control provided with your humidifier is mounted either in your return TABLE 1 – Display Panel air duct or on a wall in the living space . The control has a set of contacts which close when the RH is below the set point .
CHECK THE HUMIDIFIER OPERATION TO REPLACE THE CANISTER Replace the canister annually and when prompted by the “Service” light . Turn the control knob to the maximum RH setting . Make sure that the Use only genuine replacement part number 8043RP or 8043LCRP . water saddle valve is open and that the humidifier is on .
EXCLUSIONS: The following are not covered by this limited warranty: BASE LIMITED WARRANTY • Labor costs including, but not limited to, costs for diagnostic calls or the removal and reinstallation of Products and/or Product parts. • Shipping and freight expenses required to ship Product replacement parts. Subject to the terms and conditions of this limited warranty, Trane U .S ., Inc .
Page 8
TABLE 1: Warranty Time Periods for Outdoor Units, Air Handlers, Packaged Air Conditioners TABLE 1 (continued) and Heat Pumps, Furnaces, Ductless Systems Cased and Uncased Coils – Trane and FURNACES (*First digit may be a “T” or an “A”): American Standard Products *UD1/*DD1, *UD1-H/ *DD1-H, *UD2/*DD2, *UE1/*DE1: COVERAGE TERMS FOR RESIDENTIAL APPLICATIONS: Pursuant to the Trane U .S ., Inc .
Page 9
Table 1A: Warranty Time Periods for Controls, Zoning Products, Humidifiers, Energy Recovery Table 1B: Warranty Time Periods for Installed Accessories in Air Handlers and Packaged Ventilators, Fans and other ventilation products, Air Cleaners, whole home Dehumidifiers. Units COVERAGE TERMS FOR RESIDENTIAL APPLICATIONS: Pursuant to the Trane U .S ., Inc . COVERAGE TERMS FOR RESIDENTIAL APPLICATIONS: Pursuant to the Trane U .S ., Inc .
Page 10
SPECIFIC TERMS FOR 3-PHASE UNITS (Models up to 5 Tons in a RESIDENTIAL Application): 3-PHASE OUTDOOR UNITS: 2TTA, 4TTA, 4TWA, 4A7C, 4A6C: 3-PHASE PACKAGED UNITS: 4TCY4, 4TCX3, 4TCC3, 4WCZ6, 4DCZ6, 4WCY4, 4DCY4, 4WCX3, 4WCC3, 4YCZ6, 4YCY4, 4YCX3, 4YCC3 Base Limited Warranty Period: Outdoor Coil, Parts –...