Calibration(Feeding Direction) - Roland VersaEXPRESS RF-640 Service Notes

Hide thumbs Also See for VersaEXPRESS RF-640:
Table of Contents

Advertisement

Calculate the amount to be calibrated with the formula as
4
shown in the fi gure.
Select [PRINT MENU]>[CALIB.DEFAULT]>[SETTING], and
5
enter the calibration value with [
Press [ENTER] key to save the setting.
Parameters can be entered with an increment of
0.01%.
(MAX. +2.00% to MIN. -2.00%)
] and [
] keys.
4-32
400 -
Calibration
=
Value
Measured
Length
SERVICE MENU
PRINT MENU
PRINT MENU
CALIB.DEFAULT
CALIB.DEFAULT
SETTING
SETTING
+0.00% + 0.15%
Measured
Length
x 100
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]